Hot stamping steel is the largest amount of high strength steel products used in white body. In order to improve the corrosion resistance and oxidation resistance of hot forming steel, a metal coating is usually hot-dipping on the surface of hot stamping steel, such as aluminum silicon coating (AS) and galvanized coating (GI). In order to study the effect of different heating time on the corrosion resistance of GI coating, the 22MnB5 steels with GI coating were heated under 3 min to 10 min at 900 °C. The corrosion resistance of the coating was evaluated by electrochemical test and neutral salt spray test. The results show that GI coating was composed of Fe3Zn10 phase and α-Fe (Zn) phase after heating at 900 °C for less than 7 min. With the increase of heating time, the Fe content in the coating increased gradually, and the impedance of the coating increased gradually. After 20 days of neutral salt spray test, white rust still appeared on the surface of the coating, and there was no corrosion to the substrate. During the corrosion process, the zinc-rich phase was corroded first. In conclusion, after heat treatment the GI coating still has good corrosion resistance, but the cathodic protection performance of the coating decreases with the increase of heating time.

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Study on Corrosion Resistance of GI Coating After Heat Treatment

  • Boming Zhang,
  • Dechao Xu,
  • Yuan Long,
  • Huaxiang Teng

摘要

Hot stamping steel is the largest amount of high strength steel products used in white body. In order to improve the corrosion resistance and oxidation resistance of hot forming steel, a metal coating is usually hot-dipping on the surface of hot stamping steel, such as aluminum silicon coating (AS) and galvanized coating (GI). In order to study the effect of different heating time on the corrosion resistance of GI coating, the 22MnB5 steels with GI coating were heated under 3 min to 10 min at 900 °C. The corrosion resistance of the coating was evaluated by electrochemical test and neutral salt spray test. The results show that GI coating was composed of Fe3Zn10 phase and α-Fe (Zn) phase after heating at 900 °C for less than 7 min. With the increase of heating time, the Fe content in the coating increased gradually, and the impedance of the coating increased gradually. After 20 days of neutral salt spray test, white rust still appeared on the surface of the coating, and there was no corrosion to the substrate. During the corrosion process, the zinc-rich phase was corroded first. In conclusion, after heat treatment the GI coating still has good corrosion resistance, but the cathodic protection performance of the coating decreases with the increase of heating time.