The inductance gauge converter has a complex structure, can be fabricated, offers high sensitivity, whilst keeping its general simplicity signal processing circuits. It is also easy to be paired with others measuring devices. Hence, the knowledge about them is very limited, and the entire converter cluster often comes with a non-commercially available module, making maintenance challenging and expensive. At present, the formula documents related to inductance measurement conversion are limited and very few, so it is difficult to calculate the design. And there has not been a single study of this type of conversion applied to displacement measurement systems. In this topic, an experimental design and a construction of experimental linear lines of inductive conversion for integration with suitable gauge mechanisms are presented. Facilitating the use, exploitation and manufacture of equipment with high sensitivity and accuracy. Master the technology of making expensive gauges. In order to manufacture and test the inductance measurement conversion on roughness measuring equipment, pressure measuring equipment, force measuring equipment ….

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

E-Shaped Inductive Sensors with Enhanced Sensitivity and Linearity for Small Displacement Measurements

  • Nguyen Thi Kim Cuc,
  • Phuc Van Duong,
  • Quang Van Vu,
  • Thanh Nhu Nguyen,
  • Dai Dinh Nguyen,
  • Duong Hai Nguyen,
  • Hung Thanh Nguyen

摘要

The inductance gauge converter has a complex structure, can be fabricated, offers high sensitivity, whilst keeping its general simplicity signal processing circuits. It is also easy to be paired with others measuring devices. Hence, the knowledge about them is very limited, and the entire converter cluster often comes with a non-commercially available module, making maintenance challenging and expensive. At present, the formula documents related to inductance measurement conversion are limited and very few, so it is difficult to calculate the design. And there has not been a single study of this type of conversion applied to displacement measurement systems. In this topic, an experimental design and a construction of experimental linear lines of inductive conversion for integration with suitable gauge mechanisms are presented. Facilitating the use, exploitation and manufacture of equipment with high sensitivity and accuracy. Master the technology of making expensive gauges. In order to manufacture and test the inductance measurement conversion on roughness measuring equipment, pressure measuring equipment, force measuring equipment ….