Study Objectives: <p>Measurement tools for sleep inertia, a common and important idiopathic hypersomnia symptom, are limited. For individuals with idiopathic hypersomnia, this post hoc analysis proposes a minimal clinically important difference (MCID) for the Sleep Inertia Visual Analog Scale (SI-VAS), which assesses difficulty waking up.</p> Methods: <p>Data from the pivotal phase 3, double-blind, placebo-controlled, randomized withdrawal study (NCT03533114) of low-sodium oxybate in adults with idiopathic hypersomnia were used to estimate an SI-VAS MCID anchored to the Patient Global Impression of Change, Idiopathic Hypersomnia Severity Scale, and Functional Outcomes of Sleep Questionnaire.</p> Results: <p>Of 109 participants included, the majority female (69.7%) and White (81.7%), most were at least moderately ill (95%) per baseline Clinical Global Impression of Severity. SI-VAS score changes were strongly associated with Patient Global Impression of Change levels (Kruskal–Wallis test statistic, 110.2; <i>P</i> &lt; .0001). Estimated mean (standard error) difference in SI-VAS scores between consecutive Patient Global Impression of Change levels was 10.9 (0.8) mm, suggesting an MCID estimate of 10–12 mm. SI-VAS was also highly correlated with Idiopathic Hypersomnia Severity Scale (Pearson <i>r</i>, 0.79; <i>P</i> &lt; .0001) and Functional Outcomes of Sleep Questionnaire (Pearson <i>r</i>, −0.74;<i> P</i> &lt; .0001). Mean (standard error) SI-VAS change per 4-unit Idiopathic Hypersomnia Severity Scale change (MCID) was 6.0 (0.3) mm and per 2-unit Functional Outcomes of Sleep Questionnaire change (cutpoint) was 8.5 (0.5) mm.</p> Conclusions: <p>Establishing an MCID strengthens the SI-VAS value, adds context for findings related to sleep inertia in individuals with idiopathic hypersomnia from the phase 3 study, and aids clinicians in identifying clinically meaningful changes in sleep inertia to improve patient outcomes.</p> <p><b>Clinical Trial Registration:</b> Registry: ClinicalTrials.gov; Name: A Multicenter Study of the Efficacy and Safety of JZP-258 in the Treatment of Idiopathic Hypersomnia (IH) With an Open-label Safety Extension; URL: <a href="https://www.clinicaltrials.gov/study/NCT03533114">https://www.clinicaltrials.gov/study/NCT03533114</a>; Identifier: NCT03533114.</p> Citation: <p>Bogan RK, Fuller DS, Whalen M, Casstevens C, Schneider LD. A minimal clinically important difference for the sleep inertia visual analog scale in idiopathic hypersomnia. <i>J Clin Sleep Med.</i> 2025;21(7):1209–1216.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A minimal clinically important difference for the sleep inertia visual analog scale in idiopathic hypersomnia

  • Richard K. Bogan,
  • Douglas S. Fuller,
  • Marisa Whalen,
  • Cristina Casstevens,
  • Logan D. Schneider

摘要

Study Objectives:

Measurement tools for sleep inertia, a common and important idiopathic hypersomnia symptom, are limited. For individuals with idiopathic hypersomnia, this post hoc analysis proposes a minimal clinically important difference (MCID) for the Sleep Inertia Visual Analog Scale (SI-VAS), which assesses difficulty waking up.

Methods:

Data from the pivotal phase 3, double-blind, placebo-controlled, randomized withdrawal study (NCT03533114) of low-sodium oxybate in adults with idiopathic hypersomnia were used to estimate an SI-VAS MCID anchored to the Patient Global Impression of Change, Idiopathic Hypersomnia Severity Scale, and Functional Outcomes of Sleep Questionnaire.

Results:

Of 109 participants included, the majority female (69.7%) and White (81.7%), most were at least moderately ill (95%) per baseline Clinical Global Impression of Severity. SI-VAS score changes were strongly associated with Patient Global Impression of Change levels (Kruskal–Wallis test statistic, 110.2; P < .0001). Estimated mean (standard error) difference in SI-VAS scores between consecutive Patient Global Impression of Change levels was 10.9 (0.8) mm, suggesting an MCID estimate of 10–12 mm. SI-VAS was also highly correlated with Idiopathic Hypersomnia Severity Scale (Pearson r, 0.79; P < .0001) and Functional Outcomes of Sleep Questionnaire (Pearson r, −0.74; P < .0001). Mean (standard error) SI-VAS change per 4-unit Idiopathic Hypersomnia Severity Scale change (MCID) was 6.0 (0.3) mm and per 2-unit Functional Outcomes of Sleep Questionnaire change (cutpoint) was 8.5 (0.5) mm.

Conclusions:

Establishing an MCID strengthens the SI-VAS value, adds context for findings related to sleep inertia in individuals with idiopathic hypersomnia from the phase 3 study, and aids clinicians in identifying clinically meaningful changes in sleep inertia to improve patient outcomes.

Clinical Trial Registration: Registry: ClinicalTrials.gov; Name: A Multicenter Study of the Efficacy and Safety of JZP-258 in the Treatment of Idiopathic Hypersomnia (IH) With an Open-label Safety Extension; URL: https://www.clinicaltrials.gov/study/NCT03533114; Identifier: NCT03533114.

Citation:

Bogan RK, Fuller DS, Whalen M, Casstevens C, Schneider LD. A minimal clinically important difference for the sleep inertia visual analog scale in idiopathic hypersomnia. J Clin Sleep Med. 2025;21(7):1209–1216.