Introduction <p>Access to simulators for percutaneous coronary interventions is limited by cost and availability and is not part of most interventional fellowship programs. We developed a cost-effective coronary intervention simulator to enhance the training of interventionalists.</p> Methods <p>Porcine hearts from 6-month-old Yorkshire pigs (heart weight 300–500&#xa0;g) were obtained from a large animal research laboratory. Guide catheters were inserted into the coronary artery ostia and secured with superglue. Polyurethane insulation foam was injected into the ventricles to maintain shape and rigidity. The guide catheter was then connected to a Tuohy valve connected to a 3-way stopcock. One connection led to a pressure infusion bag filled with tap water (inflated at &gt; 300&#xa0;mmHg); the other was used for contrast injection. The heart was set on a radiolucent box with a fluid collector underneath. Clinical scenarios were simulated using 3D-printed stenoses and occlusions, blood clots for occlusive myocardial infarction, balloon oversizing for dissections, and needle trauma for perforations.</p> Results <p>The simulator was used to practice managing perforations, bifurcation-stenting, dissections, and acute coronary occlusions. Assembly, setup, and simulation times until refilling were 50, 25, and 30&#xa0;min, respectively. Intravascular imaging with Optical Coherence Tomography was successfully used to guide interventions. The simulator was frozen and reused three times without notable deterioration.</p> Conclusion <p>Our model can train a wide range of scenarios. The ability to be frozen for on-demand training enhances its utility. Limitations include the absence of pulsatile flow, heart movement, and the lack of guide catheter manipulation.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Enhancing interventional cardiology training: a porcine heart-based coronary intervention simulator

  • Joerg Reifart,
  • Paul Iaizzo

摘要

Introduction

Access to simulators for percutaneous coronary interventions is limited by cost and availability and is not part of most interventional fellowship programs. We developed a cost-effective coronary intervention simulator to enhance the training of interventionalists.

Methods

Porcine hearts from 6-month-old Yorkshire pigs (heart weight 300–500 g) were obtained from a large animal research laboratory. Guide catheters were inserted into the coronary artery ostia and secured with superglue. Polyurethane insulation foam was injected into the ventricles to maintain shape and rigidity. The guide catheter was then connected to a Tuohy valve connected to a 3-way stopcock. One connection led to a pressure infusion bag filled with tap water (inflated at > 300 mmHg); the other was used for contrast injection. The heart was set on a radiolucent box with a fluid collector underneath. Clinical scenarios were simulated using 3D-printed stenoses and occlusions, blood clots for occlusive myocardial infarction, balloon oversizing for dissections, and needle trauma for perforations.

Results

The simulator was used to practice managing perforations, bifurcation-stenting, dissections, and acute coronary occlusions. Assembly, setup, and simulation times until refilling were 50, 25, and 30 min, respectively. Intravascular imaging with Optical Coherence Tomography was successfully used to guide interventions. The simulator was frozen and reused three times without notable deterioration.

Conclusion

Our model can train a wide range of scenarios. The ability to be frozen for on-demand training enhances its utility. Limitations include the absence of pulsatile flow, heart movement, and the lack of guide catheter manipulation.