Background <p>Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.</p> Materials and methods <p>In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.5-T MRI protocols, including Dixon sequences. Two musculoskeletal radiologists independently evaluated images and performed quantitative measurements of %drop and %fat. Final diagnoses were established through histopathology (<i>n</i> = 96) or imaging follow-up (<i>n</i> = 76). Diagnostic value was assessed using area under the receiver operating characteristic curve (AUROC), inter-reader reliability using Cohen’s κ coefficient.</p> Results <p>The consensus optimal cutoff was for %drop ≤ 19.8%, yielding 87.2% accuracy, 95.3% sensitivity, and 73.8% specificity, and that for %fat was ≤ 18.3%, achieving 86.6% accuracy, 96.3% sensitivity, and 70.8% specificity. Both metrics showed high diagnostic performance (AUROC 0.824–0.863) and excellent inter-reader reliability (κ &gt; 0.93, <i>p</i> &lt; 0.001). Multivariate analysis identified %drop ≤ 19.8% and %fat ≤ 18.3% as the strongest independent predictors of malignancy, with odds ratio (OR) being 9.38 and 8.85, respectively (<i>p</i> &lt; 0.001). Signal characteristics on Dixon sequences provided additional diagnostic value, with signal voids on fat-only images (OR 7.14) and high signals on water-only images (OR 5.46).</p> Conclusion <p>Quantitative MRI Dixon imaging parameters demonstrated high diagnostic accuracy and excellent inter-reader reliability in differentiating benign and malignant BM lesions, supporting their implementation in clinical practice protocols as a reproducible adjunct to conventional MRI.</p> Relevance statement <p>Quantitative Dixon MRI provides reproducible, noninvasive differentiation of bone marrow lesions with high diagnostic accuracy across anatomical sites, enhancing clinical decision-making with standardized thresholds while demonstrating excellent inter-center consistency.</p> Key Points <p><UnorderedList Mark="Bullet"> <ItemContent> <p>Quantitative Dixon MRI thresholds of %drop ≤ 19.8% and %fat ≤ 18.3% were established as reliable predictors of malignancy in bone marrow lesions.</p> </ItemContent> <ItemContent> <p>Dixon metrics demonstrated superior diagnostic accuracy (86.6–87.2%), compared to conventional T1-weighted sequences (79.2%).</p> </ItemContent> <ItemContent> <p>Excellent inter-reader reliability (κ = 0.895–0.943) supports the reproducibility of quantitative Dixon MRI in clinical practice.</p> </ItemContent> </UnorderedList></p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Quantitative MRI Dixon signal drop and fat fraction for differentiating bone marrow lesions: a two-center prospective analysis

  • Maha Ibrahim Metwally,
  • Yassir Edrees Almalki,
  • Marwa Fathy Khalil,
  • Ahmed Mohamed Alsowey,
  • Hazem Ibrahim Aly Tantawy,
  • Mohamed Gaber Hamed,
  • Shimaa Abdelmoneem,
  • Sharifa Khalid Alduraibi,
  • Ziyad A. Almushayti,
  • Shaker Hassan S. Alshehri,
  • Ahmed M. Abdelkhalik Basha,
  • Mohammad Abd Alkhalik Basha

摘要

Background

Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.

Materials and methods

In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.5-T MRI protocols, including Dixon sequences. Two musculoskeletal radiologists independently evaluated images and performed quantitative measurements of %drop and %fat. Final diagnoses were established through histopathology (n = 96) or imaging follow-up (n = 76). Diagnostic value was assessed using area under the receiver operating characteristic curve (AUROC), inter-reader reliability using Cohen’s κ coefficient.

Results

The consensus optimal cutoff was for %drop ≤ 19.8%, yielding 87.2% accuracy, 95.3% sensitivity, and 73.8% specificity, and that for %fat was ≤ 18.3%, achieving 86.6% accuracy, 96.3% sensitivity, and 70.8% specificity. Both metrics showed high diagnostic performance (AUROC 0.824–0.863) and excellent inter-reader reliability (κ > 0.93, p < 0.001). Multivariate analysis identified %drop ≤ 19.8% and %fat ≤ 18.3% as the strongest independent predictors of malignancy, with odds ratio (OR) being 9.38 and 8.85, respectively (p < 0.001). Signal characteristics on Dixon sequences provided additional diagnostic value, with signal voids on fat-only images (OR 7.14) and high signals on water-only images (OR 5.46).

Conclusion

Quantitative MRI Dixon imaging parameters demonstrated high diagnostic accuracy and excellent inter-reader reliability in differentiating benign and malignant BM lesions, supporting their implementation in clinical practice protocols as a reproducible adjunct to conventional MRI.

Relevance statement

Quantitative Dixon MRI provides reproducible, noninvasive differentiation of bone marrow lesions with high diagnostic accuracy across anatomical sites, enhancing clinical decision-making with standardized thresholds while demonstrating excellent inter-center consistency.

Key Points

Quantitative Dixon MRI thresholds of %drop ≤ 19.8% and %fat ≤ 18.3% were established as reliable predictors of malignancy in bone marrow lesions.

Dixon metrics demonstrated superior diagnostic accuracy (86.6–87.2%), compared to conventional T1-weighted sequences (79.2%).

Excellent inter-reader reliability (κ = 0.895–0.943) supports the reproducibility of quantitative Dixon MRI in clinical practice.

Graphical Abstract