Background <p>When foreign bodies are located deep within the tissue, removal is often difficult. In recent years, computer-assisted surgery (CAS) has been widely adopted in surgery, including the removal of foreign bodies. Among various techniques, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has been widely employed for hard tissue management in the oral and maxillofacial region, and reports on the application of CAD/CAM technology for procedures involving soft tissues are lacking. In this study, we report a case in which CAD/CAM technology is used to facilitate the removal of a foreign body located in the soft tissue.</p> Case presentation <p>A 25-year-old female underwent metal plate and screw removal in 2020; however, a metal fragment remained lodged in the buccal soft tissue on the left side of the lower jaw. Computed tomography (CT) revealed a high-density area, indicating a metal fragment measuring 1.5 × 1.3 × 2.5&#xa0;mm. We identified the exact location of the fragment using preoperative CT data processed with Mimics<sup>®</sup> (Materialise). A surgical guide was designed using Magics<sup>®</sup> (Materialise) and fabricated using a 3D printer, enabling precise identification of the vertical and horizontal positions of the foreign body within the soft tissue. The use of CAD/CAM technology facilitated accurate localization and rapid removal of the fragment. The operative time of removal was 1&#xa0;h and 5&#xa0;min. Minimal bleeding occurred, and the postoperative course was uneventful, with no signs of infection or nerve damage.</p> Conclusions <p>This case demonstrates the successful application of CAD/CAM technology for the identification and removal of a foreign body from soft tissue.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Using computer-aided design/computer-aided manufacturing technology for foreign body removal from soft tissues: a case report

  • Teruhide Hoshino,
  • Shuji Yoshida,
  • Chihiro Kurihara,
  • Koki Oiwa,
  • Kotaro Tachizawa,
  • Keisuke Sugahara,
  • Akira Katakura

摘要

Background

When foreign bodies are located deep within the tissue, removal is often difficult. In recent years, computer-assisted surgery (CAS) has been widely adopted in surgery, including the removal of foreign bodies. Among various techniques, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has been widely employed for hard tissue management in the oral and maxillofacial region, and reports on the application of CAD/CAM technology for procedures involving soft tissues are lacking. In this study, we report a case in which CAD/CAM technology is used to facilitate the removal of a foreign body located in the soft tissue.

Case presentation

A 25-year-old female underwent metal plate and screw removal in 2020; however, a metal fragment remained lodged in the buccal soft tissue on the left side of the lower jaw. Computed tomography (CT) revealed a high-density area, indicating a metal fragment measuring 1.5 × 1.3 × 2.5 mm. We identified the exact location of the fragment using preoperative CT data processed with Mimics® (Materialise). A surgical guide was designed using Magics® (Materialise) and fabricated using a 3D printer, enabling precise identification of the vertical and horizontal positions of the foreign body within the soft tissue. The use of CAD/CAM technology facilitated accurate localization and rapid removal of the fragment. The operative time of removal was 1 h and 5 min. Minimal bleeding occurred, and the postoperative course was uneventful, with no signs of infection or nerve damage.

Conclusions

This case demonstrates the successful application of CAD/CAM technology for the identification and removal of a foreign body from soft tissue.