Background <p>In dynamic PET with tracer kinetic modeling, model complexity is an important but often under-recognised challenge affecting robust parameter estimation, particularly for noisy data. Traditional methods often neglect tissue heterogeneity and apply a single model universally. We applied a model selection approach alongside delay and motion correction, enabling the selection of models with varying complexity to better account for tissue heterogeneity.</p> Results <p>The study included five subjects with breast cancer undergoing dynamic <sup>18</sup>F-FDG PET imaging using a long axial field of view scanner. Voxel-wise kinetic model parameter estimation utilized five compartmental models, with the best model chosen using the Akaike Information Criterion. The model selection revealed diverse kinetic models within breast cancer lesions voxel-wise, with reduced parameter estimation variability attributed to the choice of simpler models. Applying delay and motion correction reduced the mean coefficient of variation in estimated kinetic parameters by 25%.</p> Conclusions <p>We applied a standard model selection approach to identify the optimal compartmental model for voxel-wise parameter estimation in long field-of-view dynamic PET imaging. Our results demonstrate that accounting for tissue heterogeneity in breast lesions is critical for accurate quantification. Additionally, delay and motion correction were shown to improve image quality, enhance quantification accuracy, and support more reliable model selection.</p> Clinical trial registration <p>Clinical trial number: not applicable.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Model selection for dynamic PET compartmental modelling of 18F-FDG uptake using a long axial field-of-view PET scanner with delay and motion correction

  • Hamed Moradi,
  • Rajat Vashistha,
  • Kieran O’Brien,
  • Amanda Hammond,
  • Axel Rominger,
  • Hasan Sari,
  • Kuangyu Shi,
  • Viktor Vegh,
  • David Reutens

摘要

Background

In dynamic PET with tracer kinetic modeling, model complexity is an important but often under-recognised challenge affecting robust parameter estimation, particularly for noisy data. Traditional methods often neglect tissue heterogeneity and apply a single model universally. We applied a model selection approach alongside delay and motion correction, enabling the selection of models with varying complexity to better account for tissue heterogeneity.

Results

The study included five subjects with breast cancer undergoing dynamic 18F-FDG PET imaging using a long axial field of view scanner. Voxel-wise kinetic model parameter estimation utilized five compartmental models, with the best model chosen using the Akaike Information Criterion. The model selection revealed diverse kinetic models within breast cancer lesions voxel-wise, with reduced parameter estimation variability attributed to the choice of simpler models. Applying delay and motion correction reduced the mean coefficient of variation in estimated kinetic parameters by 25%.

Conclusions

We applied a standard model selection approach to identify the optimal compartmental model for voxel-wise parameter estimation in long field-of-view dynamic PET imaging. Our results demonstrate that accounting for tissue heterogeneity in breast lesions is critical for accurate quantification. Additionally, delay and motion correction were shown to improve image quality, enhance quantification accuracy, and support more reliable model selection.

Clinical trial registration

Clinical trial number: not applicable.