Abstract <p>The International Agency for Research on Cancer categorized nitrosamines as potential or probable human carcinogens. Hence, nitrosamine impurities should be controlled to minimize the cancer risk. Sustainable Development Goal 9 (SDG9: Industry, Innovation, and Infrastructure), Target 9.4 was realized by developing a simple and straightforward LC-APCI-MS/MS method for simultaneous determination of potential nitrosamines: N-nitroso dimethylamine, N-nitroso di isopropyl amine, N-nitroso isopropyl ethylamine and N-nitroso methyl aminopyridine (NDMA, NDIPA, NIPEA and NMAP) in Sitagliptin Phosphate Monohydrate API (STG-API), an antidiabetic medication for type-2 diabetes and validated as per ICH (Q2 R2) guidelines. As a part of SDG9 (Industry, Innovation, and Infrastructure), Target 9.4, greater adoption of clean and environmentally sound technologies is possible by using the current analytical method in view of (a) less consumption of solvents as it has a lower run time of 18&#xa0;min (b) at-line sample collection (c) simple sample preparation (d) sample preparation process that does not require derivatization or sample extraction. The optimized LC method conditions are an Agilent Poroshell EC C18 column, a flow rate of 0.6&#xa0;mL/min, an injection volume of 40&#xa0;µL, a column oven temperature set at 50&#xa0;°C, and a sample cooler temperature set at 6&#xa0;°C. A gradient method was adopted using a mixture of mobile phases (Solvent A: 0.1% formic acid in water and Solvent B: a mixture of 50% Methanol and 50% Acetonitrile). The response was obtained with Multiple Reaction Monitoring (MRM) in APCI mode. The current method can quantify NDMA, NIPEA, NDIPA, and NMAP to a lower level of 74.19&#xa0;ng/g, 19.62&#xa0;ng/g, 20.36&#xa0;ng/g, and 13.65&#xa0;ng/g, respectively, which is less than 10% of the specified limits. Good linearity in the range of Limit of Quantitation (LOQ) to 150% of the specification limit was observed, with correlation coefficients higher than 0.996. The recoveries were over the range between 90.23 and 103.36%. Assessed the method’s eco-friendliness by greenness tools like the Modified Green Analytical Procedure Index (MoGAPI), ComplexMoGAPI, Analytical GREEnness (AGREE), and Analytical Eco-Scale, and found it to be eco-friendly.</p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Green and sustainable LC-APCI-MS/MS method for simultaneous quantification of genotoxic nitrosamines in antidiabetic medication: sitagliptin

  • Sriram Pepakayala,
  • Venkata Nadh Ratnakaram,
  • Yuvaraj Zunjarrao,
  • Yogesh Kumar Lohia

摘要

Abstract

The International Agency for Research on Cancer categorized nitrosamines as potential or probable human carcinogens. Hence, nitrosamine impurities should be controlled to minimize the cancer risk. Sustainable Development Goal 9 (SDG9: Industry, Innovation, and Infrastructure), Target 9.4 was realized by developing a simple and straightforward LC-APCI-MS/MS method for simultaneous determination of potential nitrosamines: N-nitroso dimethylamine, N-nitroso di isopropyl amine, N-nitroso isopropyl ethylamine and N-nitroso methyl aminopyridine (NDMA, NDIPA, NIPEA and NMAP) in Sitagliptin Phosphate Monohydrate API (STG-API), an antidiabetic medication for type-2 diabetes and validated as per ICH (Q2 R2) guidelines. As a part of SDG9 (Industry, Innovation, and Infrastructure), Target 9.4, greater adoption of clean and environmentally sound technologies is possible by using the current analytical method in view of (a) less consumption of solvents as it has a lower run time of 18 min (b) at-line sample collection (c) simple sample preparation (d) sample preparation process that does not require derivatization or sample extraction. The optimized LC method conditions are an Agilent Poroshell EC C18 column, a flow rate of 0.6 mL/min, an injection volume of 40 µL, a column oven temperature set at 50 °C, and a sample cooler temperature set at 6 °C. A gradient method was adopted using a mixture of mobile phases (Solvent A: 0.1% formic acid in water and Solvent B: a mixture of 50% Methanol and 50% Acetonitrile). The response was obtained with Multiple Reaction Monitoring (MRM) in APCI mode. The current method can quantify NDMA, NIPEA, NDIPA, and NMAP to a lower level of 74.19 ng/g, 19.62 ng/g, 20.36 ng/g, and 13.65 ng/g, respectively, which is less than 10% of the specified limits. Good linearity in the range of Limit of Quantitation (LOQ) to 150% of the specification limit was observed, with correlation coefficients higher than 0.996. The recoveries were over the range between 90.23 and 103.36%. Assessed the method’s eco-friendliness by greenness tools like the Modified Green Analytical Procedure Index (MoGAPI), ComplexMoGAPI, Analytical GREEnness (AGREE), and Analytical Eco-Scale, and found it to be eco-friendly.

Graphical Abstract