<p>Water contaminated with heavy metal ions poses serious threat to the human health and environment protection. It is imperative to develop analytical tools to detect heavy metal ions. Herein, we propose autofluorescence free SiO<sub>2</sub> modified upconversion nanosensor for label-free and fast determination of MnO<sub>4</sub><sup>−</sup> and Cr<sub>2</sub>O<sub>7</sub><sup>2−</sup> anions. The highly efficient and multi-colour upconversion luminescence (UCL) of UCNPs@SiO<sub>2</sub> was effectively quenched by MnO<sub>4</sub><sup>−</sup> and Cr<sub>2</sub>O<sub>7</sub><sup>2−</sup> anions with fast response time of 2 and 1&#xa0;min, respectively. The UCNPs@SiO<sub>2</sub> nanosensor exhibits linear detection ranges of 0.6–2000, 2–2000 µM with the LOD at 0.15, 0.04 µM for MnO<sub>4</sub><sup>−</sup> and Cr<sub>2</sub>O<sub>7</sub><sup>2−</sup> anions, respectively. The nanosensor was successfully applied for real lake and tap water samples with satisfactory results. The UCNPs@SiO<sub>2</sub> UCL nanosensor demonstrates autofluorescence free and fast determination of MnO<sub>4</sub><sup>−</sup> and Cr<sub>2</sub>O<sub>7</sub><sup>2−</sup> anions with high sensitivity, good specificity, low LOD, and wide linear detection range, holding great potential for food and environmental sample sensing.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Label-free upconversion nanosensor for water safety monitoring of permanganate and dichromate ions

  • Kuncheng Xu,
  • Hongli Wen,
  • Wei Song,
  • Abdur Raheem Aleem,
  • Murugavelu Marimuthu,
  • Wang Chen,
  • Qiuqiang Zhan,
  • Deshmukh Abdul Hakeem,
  • Saleh T. Mahmoud

摘要

Water contaminated with heavy metal ions poses serious threat to the human health and environment protection. It is imperative to develop analytical tools to detect heavy metal ions. Herein, we propose autofluorescence free SiO2 modified upconversion nanosensor for label-free and fast determination of MnO4 and Cr2O72− anions. The highly efficient and multi-colour upconversion luminescence (UCL) of UCNPs@SiO2 was effectively quenched by MnO4 and Cr2O72− anions with fast response time of 2 and 1 min, respectively. The UCNPs@SiO2 nanosensor exhibits linear detection ranges of 0.6–2000, 2–2000 µM with the LOD at 0.15, 0.04 µM for MnO4 and Cr2O72− anions, respectively. The nanosensor was successfully applied for real lake and tap water samples with satisfactory results. The UCNPs@SiO2 UCL nanosensor demonstrates autofluorescence free and fast determination of MnO4 and Cr2O72− anions with high sensitivity, good specificity, low LOD, and wide linear detection range, holding great potential for food and environmental sample sensing.