Background <p>Pediatric supracondylar humerus fractures are among the most common elbow injuries in children and require stable fixation to prevent complications. Kirschner (K) wire osteosynthesis is a widely used technique; however, the optimal wire configuration remains a subject of debate.</p> Objective <p>This study aims to investigate the effects of three different K-wire configurations (crossed, medial-parallel, and lateral-parallel) on the fixation stability of pediatric supracondylar humerus fractures using finite element analysis (FEA).</p> Methods <p>A three-dimensional finite element model of a pediatric humerus with a supracondylar fracture was constructed. Each of the three K-wire configurations was virtually applied to the model. To replicate physiological conditions, force (Z-axis) and moment (X- and Y-axes) components were applied under various loading scenarios, both individually and in combination. Mechanical parameters, including displacement, stress distribution, and rigidity, were analyzed for each configuration.</p> Results <p>The crossed K-wire configuration demonstrated superior structural stability compared to both medial-parallel and lateral-parallel configurations. It exhibited lower displacement values and more favorable stress distribution, particularly under rotational loading conditions, indicating higher mechanical resistance.</p> Conclusion <p>The findings suggest that the crossed K-wire configuration provides enhanced fixation stability and may be the most effective technique for the surgical treatment of pediatric supracondylar humerus fractures. Additionally, this study confirms the utility of finite element analysis as a robust and reliable method for evaluating the biomechanical performance of orthopedic fixation methods.</p> Graphical abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Kirschner wire configuration and fixation stability in pediatric supracondylar humerus fractures: a finite element analysis

  • Bedrettin Akar,
  • Osman Iyibilgin,
  • Yusuf Oztürkmen,
  • Süleyman Soydas,
  • Mücahid Osman Yücel

摘要

Background

Pediatric supracondylar humerus fractures are among the most common elbow injuries in children and require stable fixation to prevent complications. Kirschner (K) wire osteosynthesis is a widely used technique; however, the optimal wire configuration remains a subject of debate.

Objective

This study aims to investigate the effects of three different K-wire configurations (crossed, medial-parallel, and lateral-parallel) on the fixation stability of pediatric supracondylar humerus fractures using finite element analysis (FEA).

Methods

A three-dimensional finite element model of a pediatric humerus with a supracondylar fracture was constructed. Each of the three K-wire configurations was virtually applied to the model. To replicate physiological conditions, force (Z-axis) and moment (X- and Y-axes) components were applied under various loading scenarios, both individually and in combination. Mechanical parameters, including displacement, stress distribution, and rigidity, were analyzed for each configuration.

Results

The crossed K-wire configuration demonstrated superior structural stability compared to both medial-parallel and lateral-parallel configurations. It exhibited lower displacement values and more favorable stress distribution, particularly under rotational loading conditions, indicating higher mechanical resistance.

Conclusion

The findings suggest that the crossed K-wire configuration provides enhanced fixation stability and may be the most effective technique for the surgical treatment of pediatric supracondylar humerus fractures. Additionally, this study confirms the utility of finite element analysis as a robust and reliable method for evaluating the biomechanical performance of orthopedic fixation methods.

Graphical abstract