Introduction <p>This study aimed to evaluate the obturation quality of furcation perforations repaired using two different calcium silicate-based materials under two different magnification levels, using micro-computed tomography analysis.</p> Methods <p>Forty-eight standardized dentin disks with artificially created perforations were randomly assigned into four groups: White MTA (Angelus, Londrina, Brazil) under 4×, Bio-C Repair (Angelus, Londrina, Brazil) under 4×, White MTA under 10×, and Bio-C Repair under 10× magnification (<i>n</i> = 12). The perforated dentin disks were bonded to a resin crown using composite resin and subsequently mounted onto a phantom head model. The repairs were performed using a dental operating microscope (DOM), and a single experienced endodontist completed all procedures. After setting, the samples underwent micro-CT scanning. The volumes of materials, gaps, and voids were measured and differences between groups were analyzed using Kruskal Wallis test, t-test and Mann Whitney U test.</p> Results <p>All samples exhibited some degree of voids and gaps. Magnification level (4× vs. 10×) did not significantly affect obturation quality (<i>p</i> &gt; 0.05). However, the type of repair material had a significant impact on the outcome. White MTA exhibited significantly fewer voids, gaps, and total unfilled volume compared to Bio-C Repair (<i>p</i> &lt; 0.05).</p> Conclusion <p>Increasing the magnification level from 4× to 10× did not improve the sealing quality in furcation perforation repair. However, White MTA demonstrated superior adaptation and condensation characteristics to Bio-C Repair, regardless of magnification. While handling the properties of powder-liquid MTA may pose clinical challenges, it remains a more effective option for achieving superior sealing in furcation perforation repairs than premixed putty formulations.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Obturation quality analysis of furcation perforations repaired with different magnifications and biomaterials

  • Mustafa Mert Tulgar,
  • Yağmur Kılıç,
  • Merve Işık Aydın,
  • Ali Keleş

摘要

Introduction

This study aimed to evaluate the obturation quality of furcation perforations repaired using two different calcium silicate-based materials under two different magnification levels, using micro-computed tomography analysis.

Methods

Forty-eight standardized dentin disks with artificially created perforations were randomly assigned into four groups: White MTA (Angelus, Londrina, Brazil) under 4×, Bio-C Repair (Angelus, Londrina, Brazil) under 4×, White MTA under 10×, and Bio-C Repair under 10× magnification (n = 12). The perforated dentin disks were bonded to a resin crown using composite resin and subsequently mounted onto a phantom head model. The repairs were performed using a dental operating microscope (DOM), and a single experienced endodontist completed all procedures. After setting, the samples underwent micro-CT scanning. The volumes of materials, gaps, and voids were measured and differences between groups were analyzed using Kruskal Wallis test, t-test and Mann Whitney U test.

Results

All samples exhibited some degree of voids and gaps. Magnification level (4× vs. 10×) did not significantly affect obturation quality (p > 0.05). However, the type of repair material had a significant impact on the outcome. White MTA exhibited significantly fewer voids, gaps, and total unfilled volume compared to Bio-C Repair (p < 0.05).

Conclusion

Increasing the magnification level from 4× to 10× did not improve the sealing quality in furcation perforation repair. However, White MTA demonstrated superior adaptation and condensation characteristics to Bio-C Repair, regardless of magnification. While handling the properties of powder-liquid MTA may pose clinical challenges, it remains a more effective option for achieving superior sealing in furcation perforation repairs than premixed putty formulations.