Background <p>The aim of this in-vitro study is to investigate the effect of post-curing time and units on the degree of conversion (DC), microhardness (VHN) and staining susceptibility (∆E<sub>00</sub>) of two 3D printed permanent resins (Crowntec (SCT), Varseosmile Crown<sup>Plus</sup> (VSP)).</p> Methods <p>A total of 180 disc-shaped samples (10*10*2&#xa0;mm), 60 for each experiment, from the tested materials (30 SCT, 30 VSP) were printed on 3D printer. Half of the samples were post-cured in LC-3DPrint Box and the other half in Phrozen Cure V2 and were divided into 3 subgroups according to post-curing time of 5, 10 and 30&#xa0;min (<i>n</i> = 5). The DC of the samples was determined using a Fourier transform infrared spectrometer. The VHN values were measured with a Vickers hardness tester. The color of the samples was initially measured using a spectrophotometer and then again after one month of staining in coffee. The ∆E<sub>00</sub> was calculated with the CIEDE2000 formula. Data obtained from each parameter examined were analyzed by SPSS software using One-Way ANOVA, post-hoc Tukey, post-hoc Tamhane’s T2, Independent-samples T test and Pearson’s correlation test (α = 0.05).</p> Results <p>While DC and VHN ​​of the tested materials increased in parallel with the post-curing time, ∆E<sub>00</sub> decreased. The highest DC (74.6 ± 3.8) and VHN (29.1 ± 0.8) and the lowest ∆E<sub>00</sub> (1.9 ± 0.1) were obtained in LC-3DPrint Box-30&#xa0;min post-curing group of VSP. The effect of the type of post-curing units on the DC and ∆E<sub>00</sub> of the materials was statistically significant (<i>p</i> &lt; 0.05) except for the SCT-5&#xa0;min and SCT-30&#xa0;min groups. The VHN was statistically significantly higher in LC-3DPrint Box at all post-curing times of the tested materials (<i>p</i> &lt; 0.05). A significant positive correlation was found between DC and VHN (<i>r</i> = 0.796, <i>p</i> &lt; 0.001), while a significant negative correlation was observed between DC and ∆E<sub>00</sub> (<i>r</i>=-0.763, <i>p</i> &lt; 0.001).</p> Conclusion <p>The study demonstrated that extending the post-curing time led to improvements in the degree of conversion and microhardness, while simultaneously reducing the stainability of the materials tested. Additionally, the type of post-curing unit used had a significant impact on these results, further highlighting the importance of both curing time and equipment in optimizing material properties.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Effects of post-curing conditions on degree of conversion, microhardness, and stainability of 3D printed permanent resins

  • Sultan Aktug Karademir,
  • Samet Atasoy,
  • Serdar Akarsu,
  • Eda Karaaslan

摘要

Background

The aim of this in-vitro study is to investigate the effect of post-curing time and units on the degree of conversion (DC), microhardness (VHN) and staining susceptibility (∆E00) of two 3D printed permanent resins (Crowntec (SCT), Varseosmile CrownPlus (VSP)).

Methods

A total of 180 disc-shaped samples (10*10*2 mm), 60 for each experiment, from the tested materials (30 SCT, 30 VSP) were printed on 3D printer. Half of the samples were post-cured in LC-3DPrint Box and the other half in Phrozen Cure V2 and were divided into 3 subgroups according to post-curing time of 5, 10 and 30 min (n = 5). The DC of the samples was determined using a Fourier transform infrared spectrometer. The VHN values were measured with a Vickers hardness tester. The color of the samples was initially measured using a spectrophotometer and then again after one month of staining in coffee. The ∆E00 was calculated with the CIEDE2000 formula. Data obtained from each parameter examined were analyzed by SPSS software using One-Way ANOVA, post-hoc Tukey, post-hoc Tamhane’s T2, Independent-samples T test and Pearson’s correlation test (α = 0.05).

Results

While DC and VHN ​​of the tested materials increased in parallel with the post-curing time, ∆E00 decreased. The highest DC (74.6 ± 3.8) and VHN (29.1 ± 0.8) and the lowest ∆E00 (1.9 ± 0.1) were obtained in LC-3DPrint Box-30 min post-curing group of VSP. The effect of the type of post-curing units on the DC and ∆E00 of the materials was statistically significant (p < 0.05) except for the SCT-5 min and SCT-30 min groups. The VHN was statistically significantly higher in LC-3DPrint Box at all post-curing times of the tested materials (p < 0.05). A significant positive correlation was found between DC and VHN (r = 0.796, p < 0.001), while a significant negative correlation was observed between DC and ∆E00 (r=-0.763, p < 0.001).

Conclusion

The study demonstrated that extending the post-curing time led to improvements in the degree of conversion and microhardness, while simultaneously reducing the stainability of the materials tested. Additionally, the type of post-curing unit used had a significant impact on these results, further highlighting the importance of both curing time and equipment in optimizing material properties.