Purpose <p>To introduce the iris-ciliary angle area (ICAA) as a novel quantitative parameter for enhancing accuracy in implantable Collamer lens (ICL) sizing and postoperative vault prediction, addressing limitations of traditional methods based on white-to-white (WTW) and anterior chamber depth (ACD), particularly in high myopia cases.</p> Methods <p>In this retrospective study of 319 eyes, sulcus-to-sulcus (STS), ICAA, and other ocular parameters were analyzed using multivariate linear regression models to assess their influence on ICL diameter and vault. Clinical validation was conducted to compare the predictive accuracy of the proposed model with conventional sizing methods.</p> Results <p>STS was identified as an independent predictor of ICL size, while ICAA, STS, axial length (AL), and ICL size were significant predictors of postoperative vault. The proposed model demonstrated significantly reduced vault prediction errors (75.06 ± 66.43&#xa0;μm) compared to the NK formula (210 ± 155&#xa0;μm), NK2 formula (201 ± 146&#xa0;μm), and Staar nomogram (189 ± 132&#xa0;μm) (<i>P</i> &lt; 0.001), despite moderate R² values, indicating improved clinical precision in ICL optimization.</p> Conclusion <p>ICAA and STS offer valuable additions to ICL selection criteria, significantly improving vault prediction accuracy compared to established formulas, with approximately 60–64% reduction in mean absolute error. The quantitative assessment of posterior chamber structures through these parameters enhances procedural reliability and surgical outcomes. Further validation is recommended for cases involving extreme vaults or rotated ICL implants to confirm the model’s broad applicability.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Quantitative analysis of iris–ciliary angle area to optimize ICL selection: a retrospective study

  • Mingyuan Lv,
  • Yunhai Dai,
  • Xiaoming Wu

摘要

Purpose

To introduce the iris-ciliary angle area (ICAA) as a novel quantitative parameter for enhancing accuracy in implantable Collamer lens (ICL) sizing and postoperative vault prediction, addressing limitations of traditional methods based on white-to-white (WTW) and anterior chamber depth (ACD), particularly in high myopia cases.

Methods

In this retrospective study of 319 eyes, sulcus-to-sulcus (STS), ICAA, and other ocular parameters were analyzed using multivariate linear regression models to assess their influence on ICL diameter and vault. Clinical validation was conducted to compare the predictive accuracy of the proposed model with conventional sizing methods.

Results

STS was identified as an independent predictor of ICL size, while ICAA, STS, axial length (AL), and ICL size were significant predictors of postoperative vault. The proposed model demonstrated significantly reduced vault prediction errors (75.06 ± 66.43 μm) compared to the NK formula (210 ± 155 μm), NK2 formula (201 ± 146 μm), and Staar nomogram (189 ± 132 μm) (P < 0.001), despite moderate R² values, indicating improved clinical precision in ICL optimization.

Conclusion

ICAA and STS offer valuable additions to ICL selection criteria, significantly improving vault prediction accuracy compared to established formulas, with approximately 60–64% reduction in mean absolute error. The quantitative assessment of posterior chamber structures through these parameters enhances procedural reliability and surgical outcomes. Further validation is recommended for cases involving extreme vaults or rotated ICL implants to confirm the model’s broad applicability.