Purpose <p>To evaluate the effect of the levator muscle-conjoint Fascial Sheath Complex Suspension on ocular biometric parameters and refractive status in children with congenital blepharoptosis.</p> Methods <p>We reviewed the clinical records of 68 patients with congenital blepharoptosis who attended our hospital from 2021 to 2023 and underwent ptosis surgery with detailed examination. The changes of corneal topography and refractive characteristics before and 1 month, 3 months, 6 months after surgery were compared and analyzed.</p> Results <p>Before surgery, ptosis eyes had statistically significant flatter flat keratometry (<i>P</i> = 0.015), thicker subfoveal choroidal thickness (<i>P</i> = 0.021), higher astigmatic magnitude(<i>P</i> = 0.006) than non-blepharoptosis eyes. The 1-month postoperative steep keratometry and the astigmatic magnitude were significantly higher than the preoperative values in unilateral ptosis (<i>P</i> = 0.032, <i>P</i> = 0.014), without affecting astigmatic power vectors and central corneal thickness (<i>P</i> &gt; 0.05); The astigmatic magnitude at 3 months after surgery were higher than the preoperative values in unilateral ptosis (<i>P</i> = 0.042). In all patients, the postoperative change of astigmatic magnitude was greatest in severe ptosis.</p> Conclusions <p>Ptosis repair surgery for congenital ptosis seems to cause increase of steep K value and astigmatism over early postoperative period but no refraction alteration over the long-term postoperative period. A significant myopic shift was observed at the 6-month postoperative follow-up in severe unilateral ptosis.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Refractive status and ocular biometric parameters in children undergoing the levator muscle-conjoint fascial sheath complex suspension

  • Ting Fu,
  • Shunguo Ma,
  • Huiyang Ai,
  • Yuan Zhang,
  • Jingmin Guo,
  • Yan Jiang,
  • Rong Liu

摘要

Purpose

To evaluate the effect of the levator muscle-conjoint Fascial Sheath Complex Suspension on ocular biometric parameters and refractive status in children with congenital blepharoptosis.

Methods

We reviewed the clinical records of 68 patients with congenital blepharoptosis who attended our hospital from 2021 to 2023 and underwent ptosis surgery with detailed examination. The changes of corneal topography and refractive characteristics before and 1 month, 3 months, 6 months after surgery were compared and analyzed.

Results

Before surgery, ptosis eyes had statistically significant flatter flat keratometry (P = 0.015), thicker subfoveal choroidal thickness (P = 0.021), higher astigmatic magnitude(P = 0.006) than non-blepharoptosis eyes. The 1-month postoperative steep keratometry and the astigmatic magnitude were significantly higher than the preoperative values in unilateral ptosis (P = 0.032, P = 0.014), without affecting astigmatic power vectors and central corneal thickness (P > 0.05); The astigmatic magnitude at 3 months after surgery were higher than the preoperative values in unilateral ptosis (P = 0.042). In all patients, the postoperative change of astigmatic magnitude was greatest in severe ptosis.

Conclusions

Ptosis repair surgery for congenital ptosis seems to cause increase of steep K value and astigmatism over early postoperative period but no refraction alteration over the long-term postoperative period. A significant myopic shift was observed at the 6-month postoperative follow-up in severe unilateral ptosis.