Background <p>Keeping the umbilical cord intact the first minutes after delivery is beneficial for both term and preterm infants. However, this may be challenging in caesarean sections (CS) due to lack of mobile resuscitation equipment, maintenance of sterility or concern for excessive maternal blood loss. The objective of this study was to develop and pilot-test extra-uterine placental transfusion and intact-cord stabilisation of infants in CS.</p> Methods <p>The intervention development process (phase 1) covered: (A) placenta delivery without cord clamping, (B) intact-cord stabilisation of the infant and (C) physiology-based cord clamping. Different scenarios were tested through in-situ simulation and adjusted through multiple feedback rounds. The involved staff were trained prior to pilot-testing (phase 2). Women having a CS in regional anaesthesia, expecting a term or near-term singleton infant were included in the pilot-study after written consent. Primary outcome was the proportion of successfully completed interventions. For assessment of safety, maternal estimated intraoperative blood loss, infant 5-minute Apgar scores and infant rectal temperature during stabilisation were compared to pre-defined accept criteria. Dry-electrode ECG (NeoBeat™) was used for early detection of infant heart rate. Any respiratory support was registered. Early skin-to-skin contact between mother and infant was attempted for vigorous infants.</p> Results <p>A detailed intervention protocol was developed and tested. Twenty-nine mother-infant-dyads were included in the pilot study. Gestational age ranged from 37 to 42 weeks. The intervention was successfully completed in 26 of 29 cases, of which 31% were planned CS. Median (SD) infant heart rates at one and five minutes were 159 (32) and 168 (21) beats per minute respectively. Eight infants (28%) had intact-cord respiratory support. One infant had a 5-minute Apgar score &lt; 7 and three infants (10%) had rectal temperatures below 36.5&#xa0;°C during the first 10–15&#xa0;min after birth. Three mothers (10%) had estimated intraoperative blood loss &gt; 1000&#xa0;ml.</p> Conclusion <p>Extra-uterine placental transfusion to facilitate intact-cord stabilisation and physiology-based cord clamping for term and near-term infants delivered by CS was feasible according to predefined accept criteria. Further investigation of safety of this complex intervention in larger, comparative studies is warranted.</p> Trial registration <p>Regional Committee for Medical Research Ethics Central Norway (REK-Midt), #399101.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Extra-uterine placental transfusion and intact-cord stabilisation of infants in caesarean sections: an intervention development and pilot-study (INTACT-1)

  • Elisabeth Saether,
  • Ola Andersson,
  • Solveig Bjellmo,
  • Stine Bernitz,
  • Friedrich Reinhart-Van Gülpen,
  • Tor Åge Myklebust,
  • Solhild Stridsklev,
  • Beate Horsberg Eriksen

摘要

Background

Keeping the umbilical cord intact the first minutes after delivery is beneficial for both term and preterm infants. However, this may be challenging in caesarean sections (CS) due to lack of mobile resuscitation equipment, maintenance of sterility or concern for excessive maternal blood loss. The objective of this study was to develop and pilot-test extra-uterine placental transfusion and intact-cord stabilisation of infants in CS.

Methods

The intervention development process (phase 1) covered: (A) placenta delivery without cord clamping, (B) intact-cord stabilisation of the infant and (C) physiology-based cord clamping. Different scenarios were tested through in-situ simulation and adjusted through multiple feedback rounds. The involved staff were trained prior to pilot-testing (phase 2). Women having a CS in regional anaesthesia, expecting a term or near-term singleton infant were included in the pilot-study after written consent. Primary outcome was the proportion of successfully completed interventions. For assessment of safety, maternal estimated intraoperative blood loss, infant 5-minute Apgar scores and infant rectal temperature during stabilisation were compared to pre-defined accept criteria. Dry-electrode ECG (NeoBeat™) was used for early detection of infant heart rate. Any respiratory support was registered. Early skin-to-skin contact between mother and infant was attempted for vigorous infants.

Results

A detailed intervention protocol was developed and tested. Twenty-nine mother-infant-dyads were included in the pilot study. Gestational age ranged from 37 to 42 weeks. The intervention was successfully completed in 26 of 29 cases, of which 31% were planned CS. Median (SD) infant heart rates at one and five minutes were 159 (32) and 168 (21) beats per minute respectively. Eight infants (28%) had intact-cord respiratory support. One infant had a 5-minute Apgar score < 7 and three infants (10%) had rectal temperatures below 36.5 °C during the first 10–15 min after birth. Three mothers (10%) had estimated intraoperative blood loss > 1000 ml.

Conclusion

Extra-uterine placental transfusion to facilitate intact-cord stabilisation and physiology-based cord clamping for term and near-term infants delivered by CS was feasible according to predefined accept criteria. Further investigation of safety of this complex intervention in larger, comparative studies is warranted.

Trial registration

Regional Committee for Medical Research Ethics Central Norway (REK-Midt), #399101.