Abstract <p>Intrinsic and mutual inductances of the central inductor, the MEPhIST-0 tokamak electromagnetic system coils PF1–PF6, and the tokamak discharge chamber are determined in the frequency range from 50 to 15&#xa0;000 Hz. It has been found that, in the low-frequency range up to ~200 Hz, in order to determine the mutual interference of the most strongly coupled coils, it is possible to represent the discharge chamber as one short-circuited turn inductively coupled with the coils of a poloidal system.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Determination of Inductive Characteristics of the MEPhIST-0 Tokamak Electromagnetic System

  • S. A. Krat,
  • D. V. Kolodko,
  • I. I. Pashkov,
  • D. L. Ulasevich,
  • A. S. Prishvitsyn,
  • N. E. Efimov,
  • F. S. Podolyako

摘要

Abstract

Intrinsic and mutual inductances of the central inductor, the MEPhIST-0 tokamak electromagnetic system coils PF1–PF6, and the tokamak discharge chamber are determined in the frequency range from 50 to 15 000 Hz. It has been found that, in the low-frequency range up to ~200 Hz, in order to determine the mutual interference of the most strongly coupled coils, it is possible to represent the discharge chamber as one short-circuited turn inductively coupled with the coils of a poloidal system.