<p>Early detection of gastric cancer (GC) is critical for improving prognosis, yet conventional biomarkers lack sensitivity and specificity, necessitating non-invasive, high-performance diagnostic tools. This study integrated untargeted metabolomics and machine learning to develop a plasma metabolite panel for GC diagnosis and mechanistic insights. Plasma and tissue samples from two cohorts (<i>n</i> = 597) were analyzed using ultra-performance liquid chromatography–mass spectrometry (UPLC-MS). A six-metabolite panel was identified and validated, demonstrating excellent diagnostic performance (area under the curve: 0.947–0.982 in discovery; 0.920–0.951 in validation) and superior sensitivity (0.900–0.940) compared to conventional markers (0.020–0.240). Isovalerylcarnitine (C5), a key component, was consistently downregulated in both plasma and tissue samples. Mendelian randomization supported a causal relationship between isovalerylcarnitine (C5) and GC risk. Proteomic analyses revealed inverse correlations between C5 and cadherin/MMP family proteins. Functional assays confirmed that isovalerylcarnitine (C5) inhibited GC cell migration and invasion via calpain-mediated cleavage of VE-cadherin and MMP2. This study identifies a robust diagnostic metabolite panel for GC detection and highlights a novel mechanistic role of isovalerylcarnitine (C5) in GC progression, supporting its utility as both a biomarker and therapeutic target.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Metabolic signatures for gastric cancer diagnosis and mechanistic insights: a multicenter study

  • Juan Zhu,
  • Yida Huang,
  • Xue Li,
  • Bin Liu,
  • Li Yuan,
  • Le Wang,
  • Kun Qian,
  • Yingying Mao,
  • Yongjie Xu,
  • Lingbin Du,
  • Xiangdong Cheng

摘要

Early detection of gastric cancer (GC) is critical for improving prognosis, yet conventional biomarkers lack sensitivity and specificity, necessitating non-invasive, high-performance diagnostic tools. This study integrated untargeted metabolomics and machine learning to develop a plasma metabolite panel for GC diagnosis and mechanistic insights. Plasma and tissue samples from two cohorts (n = 597) were analyzed using ultra-performance liquid chromatography–mass spectrometry (UPLC-MS). A six-metabolite panel was identified and validated, demonstrating excellent diagnostic performance (area under the curve: 0.947–0.982 in discovery; 0.920–0.951 in validation) and superior sensitivity (0.900–0.940) compared to conventional markers (0.020–0.240). Isovalerylcarnitine (C5), a key component, was consistently downregulated in both plasma and tissue samples. Mendelian randomization supported a causal relationship between isovalerylcarnitine (C5) and GC risk. Proteomic analyses revealed inverse correlations between C5 and cadherin/MMP family proteins. Functional assays confirmed that isovalerylcarnitine (C5) inhibited GC cell migration and invasion via calpain-mediated cleavage of VE-cadherin and MMP2. This study identifies a robust diagnostic metabolite panel for GC detection and highlights a novel mechanistic role of isovalerylcarnitine (C5) in GC progression, supporting its utility as both a biomarker and therapeutic target.