<p>Chikungunya virus (CHIKV) induces a massive cytopathic effect (CPE) on various cell types. Therefore, the plaque assay, a CPE-based virus titration method, remains the gold standard for quantifying the infectious units of CHIKV. However, manual plaque counting is often a labor-intensive task, especially in experiments involving multiple samples. In this study, we developed plaQuest, a stand-alone plaque-counting software running on a Windows operating system, for rapid and reliable quantification of CHIKV plaques in a 24-well plate. Our evaluation experiments using the conventional CPE-based plaque assay showed that the CHIKV plaque counts provided by plaQuest strongly correlated with the plaque counts manually determined by four analysts. In addition, the CHIKV inhibition curve of mycophenolic acid (MPA) determined by plaQuest was identical to that determined by manual counting, resulting in a similar 50% inhibitory concentration of MPA. Furthermore, the automated plaque counting by plaQuest was applicable to the evaluation of inhibitors against other RNA viruses using the CPE-based and immunostain-based plaque assay, which is an alternative titration assay for non- (or less) cytopathic viruses. Thus, our study demonstrates that plaQuest is an effective option for quantifying infectious virus titers, reducing the workload of the plaque assay.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Development of an automated plaque-counting program for the quantification of the Chikungunya virus

  • Akino Emi,
  • Youichi Suzuki,
  • Chinami Odake,
  • Shoichi Sakaguchi,
  • Hong Wu,
  • Takashi Nakano

摘要

Chikungunya virus (CHIKV) induces a massive cytopathic effect (CPE) on various cell types. Therefore, the plaque assay, a CPE-based virus titration method, remains the gold standard for quantifying the infectious units of CHIKV. However, manual plaque counting is often a labor-intensive task, especially in experiments involving multiple samples. In this study, we developed plaQuest, a stand-alone plaque-counting software running on a Windows operating system, for rapid and reliable quantification of CHIKV plaques in a 24-well plate. Our evaluation experiments using the conventional CPE-based plaque assay showed that the CHIKV plaque counts provided by plaQuest strongly correlated with the plaque counts manually determined by four analysts. In addition, the CHIKV inhibition curve of mycophenolic acid (MPA) determined by plaQuest was identical to that determined by manual counting, resulting in a similar 50% inhibitory concentration of MPA. Furthermore, the automated plaque counting by plaQuest was applicable to the evaluation of inhibitors against other RNA viruses using the CPE-based and immunostain-based plaque assay, which is an alternative titration assay for non- (or less) cytopathic viruses. Thus, our study demonstrates that plaQuest is an effective option for quantifying infectious virus titers, reducing the workload of the plaque assay.