<p>The potential of the sequence in Coronary Angiography (CA) frames for diagnosing coronary artery disease (CAD) has been largely overlooked. Our study aims to reveal the “Sequence Value” embedded within these frames and to explore methods for its application in diagnostics. We conduct a survey via Amazon Mturk (Mechanical Turk) to evaluate the effectiveness of Sequence Restoration Capability in indicating CAD. Furthermore, we develop a self-supervised deep learning model to automatically assess this capability. Additionally, we ensure the robustness of our results by differently selecting coronary angiographies/modules for statistical analysis. Our self-supervised deep learning model achieves an average AUC of 80.1% across five-fold validation, demonstrating robustness against static data noise and efficiency, with calculations completed within 30&#xa0;s. This study uncovers significant insights into CAD diagnosis through the sequence value in coronary angiography. We successfully illustrate methodologies for harnessing this potential, contributing valuable knowledge to the field.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Linking sequence restoration capability of shuffled coronary angiography to coronary artery disease diagnosis

  • Yanan Dai,
  • Pengxiong Zhu,
  • Yunhao Xie,
  • Bangde Xue,
  • Yun Ling,
  • Xibao Shi,
  • Liang Geng,
  • Jian-Qiang Hu,
  • Qi Zhang,
  • Jun Liu

摘要

The potential of the sequence in Coronary Angiography (CA) frames for diagnosing coronary artery disease (CAD) has been largely overlooked. Our study aims to reveal the “Sequence Value” embedded within these frames and to explore methods for its application in diagnostics. We conduct a survey via Amazon Mturk (Mechanical Turk) to evaluate the effectiveness of Sequence Restoration Capability in indicating CAD. Furthermore, we develop a self-supervised deep learning model to automatically assess this capability. Additionally, we ensure the robustness of our results by differently selecting coronary angiographies/modules for statistical analysis. Our self-supervised deep learning model achieves an average AUC of 80.1% across five-fold validation, demonstrating robustness against static data noise and efficiency, with calculations completed within 30 s. This study uncovers significant insights into CAD diagnosis through the sequence value in coronary angiography. We successfully illustrate methodologies for harnessing this potential, contributing valuable knowledge to the field.