<p>The Coronavirus disease 2019 (COVID-19) pandemic has caused significant global threats, as Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is primarily transmitted through airborne droplets and bioaerosols. Healthcare workers are particularly at high risk, yet there is limited research on the presence of SARS-CoV-2 in bioaerosols within healthcare facilities in Malaysia. This study aimed to determine the presence and viability of SARS-CoV-2 and its variants of concern in the air and ventilation systems of designated COVID-19 facilities from December 2021 to February 2022. Samples were collected from two hospitals and one quarantine centre (QC), including medical wards, intensive care units, emergency departments, and QC halls. Air samples were obtained using air samplers, while surface samples were taken from return air grilles. SARS-CoV-2 ribonucleic acid (RNA) and its variants were detected using reverse transcription droplet digital polymerase chain reaction (RT-ddPCR) and PCR-based genotyping, respectively. Results showed that Hospital A had a higher rate (24.6%) of positive samples than Hospital B (8.8%). Surface samples had a higher positivity rate (50.0%) compared to air samples (8.3%). The detected variants included delta (34.7%), a mixture of delta and omicron (8.7%), non-variant of concern (non-VOC) (8.7%), and omicron (4.3%). This study emphasizes the need for strict airborne infection control measures for healthcare workers.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Detection of SARS-CoV-2 in bioaerosols and surface samples from healthcare facilities in Klang Valley, Malaysia

  • Rosnawati Muhammad Robat,
  • Raheel Nazakat,
  • Siti Aishah Rashid,
  • Rohaida Ismail,
  • Nurul Amalina Khairul Hasni,
  • Nadia Mohamad,
  • Nik Muhammad Nizam Nik Hassan,
  • Muhammad Alfatih Pahrol,
  • Jeyanthi Suppiah,
  • Fatin Amirah Suib,
  • Kamesh Rajendran,
  • Rafiza Shaharudin

摘要

The Coronavirus disease 2019 (COVID-19) pandemic has caused significant global threats, as Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is primarily transmitted through airborne droplets and bioaerosols. Healthcare workers are particularly at high risk, yet there is limited research on the presence of SARS-CoV-2 in bioaerosols within healthcare facilities in Malaysia. This study aimed to determine the presence and viability of SARS-CoV-2 and its variants of concern in the air and ventilation systems of designated COVID-19 facilities from December 2021 to February 2022. Samples were collected from two hospitals and one quarantine centre (QC), including medical wards, intensive care units, emergency departments, and QC halls. Air samples were obtained using air samplers, while surface samples were taken from return air grilles. SARS-CoV-2 ribonucleic acid (RNA) and its variants were detected using reverse transcription droplet digital polymerase chain reaction (RT-ddPCR) and PCR-based genotyping, respectively. Results showed that Hospital A had a higher rate (24.6%) of positive samples than Hospital B (8.8%). Surface samples had a higher positivity rate (50.0%) compared to air samples (8.3%). The detected variants included delta (34.7%), a mixture of delta and omicron (8.7%), non-variant of concern (non-VOC) (8.7%), and omicron (4.3%). This study emphasizes the need for strict airborne infection control measures for healthcare workers.