<p>This study is a biomechanical cadaveric investigation to assess bone healing by measuring frequency changes using a new plate design called bone union detection with wire’s natural frequency (BUDWF). Based on natural frequency and strain theory, in bone fracture conditions, the plate experiences higher strain under axial load and generates higher frequency, compared to the bone union condition where strain is lower and frequency is lower. If frequency changes can be detected, they can be used to determine the bone healing status. Eight human cadaveric tibia bones were used in the experiment. Bone union and fracture with a 10&#xa0;mm gap, fixed by the BUDWF plate, were tested under various axial loads (0&#xa0;N, 100&#xa0;N, 200&#xa0;N, 300&#xa0;N, and 400&#xa0;N) using the “Instron Electropuls E10000”. We found that the frequency did not significantly change with any axial loads in bone healing, which is different from the bone fracture where the frequency was higher under high axial load. When comparing the two bone conditions, there were significant differences in frequency change under axial loads of 200, 300, and 400&#xa0;N (<i>p</i> &lt; 0.001). From the result, The BUDWF plate with frequency measurement can assess bone healing by comparing the frequency changes from the bone fracture and the bone union condition under an axial load of 400&#xa0;N. We hope this plate will be the prototype for developing the device to help bone healing detection in the future.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

New design of plate implant for bone healing assessment using frequency measurement: a biomechanical cadaveric study

  • Chavarin Amarase,
  • Pairat Tangpornprasert,
  • Chanyaphan Virulsri,
  • Pisitpong Chancharoen,
  • Saran Tantavisut

摘要

This study is a biomechanical cadaveric investigation to assess bone healing by measuring frequency changes using a new plate design called bone union detection with wire’s natural frequency (BUDWF). Based on natural frequency and strain theory, in bone fracture conditions, the plate experiences higher strain under axial load and generates higher frequency, compared to the bone union condition where strain is lower and frequency is lower. If frequency changes can be detected, they can be used to determine the bone healing status. Eight human cadaveric tibia bones were used in the experiment. Bone union and fracture with a 10 mm gap, fixed by the BUDWF plate, were tested under various axial loads (0 N, 100 N, 200 N, 300 N, and 400 N) using the “Instron Electropuls E10000”. We found that the frequency did not significantly change with any axial loads in bone healing, which is different from the bone fracture where the frequency was higher under high axial load. When comparing the two bone conditions, there were significant differences in frequency change under axial loads of 200, 300, and 400 N (p < 0.001). From the result, The BUDWF plate with frequency measurement can assess bone healing by comparing the frequency changes from the bone fracture and the bone union condition under an axial load of 400 N. We hope this plate will be the prototype for developing the device to help bone healing detection in the future.