<p>This research investigates the potential of a sectoral Cylindrical Dielectric Resonator Antenna (CDRA) for biomedical telemetry. CDRAs are known for their low-loss, ruggedness, and stability, but their limited bandwidth and size make them unsuitable for wearable devices. The research addresses these limitations by proposing a dual-mode antenna that operates in <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2025_17595_Article_IEq1.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="48" /> </InlineMediaObject> <EquationSource Format="TEX">\(\:{EH}_{110}\)</EquationSource> </InlineEquation> and <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2025_17595_Article_IEq2.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="45" /> </InlineMediaObject> <EquationSource Format="TEX">\(\:{TE}_{210}\)</EquationSource> </InlineEquation> modes. The sectoral CDRA is a quarter segment with Perfect Electric Conductor boundaries, reducing its size by a factor of four. Mathematical derivations of the field components for both modes are derived to support the design. To minimize specific absorption rate (SAR), an Artificial Magnetic Conductor (AMC) surface is applied to the antenna’s backside, enhancing compatibility with the transverse electric modes. The antenna achieves a bandwidth of 0.7&#xa0;GHz (5.2–5.9&#xa0;GHz), suitable for biomedical applications, with a measured peak gain of 7.9 dBi and a SAR of 1.24&#xa0;W/kg when applied to a human arm.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Artificial magnetic conductor backed dual-mode sectoral cylindrical DRA for off-body biomedical telemetry

  • Nayab Gogosh,
  • Sohail Khalid,
  • Bilal Tariq Malik,
  • Slawomir Koziel

摘要

This research investigates the potential of a sectoral Cylindrical Dielectric Resonator Antenna (CDRA) for biomedical telemetry. CDRAs are known for their low-loss, ruggedness, and stability, but their limited bandwidth and size make them unsuitable for wearable devices. The research addresses these limitations by proposing a dual-mode antenna that operates in \(\:{EH}_{110}\) and \(\:{TE}_{210}\) modes. The sectoral CDRA is a quarter segment with Perfect Electric Conductor boundaries, reducing its size by a factor of four. Mathematical derivations of the field components for both modes are derived to support the design. To minimize specific absorption rate (SAR), an Artificial Magnetic Conductor (AMC) surface is applied to the antenna’s backside, enhancing compatibility with the transverse electric modes. The antenna achieves a bandwidth of 0.7 GHz (5.2–5.9 GHz), suitable for biomedical applications, with a measured peak gain of 7.9 dBi and a SAR of 1.24 W/kg when applied to a human arm.