<p>One of the many environmental contamination issues around the world is the safer detection or sensing of heavy metal ions. Between all metal ions, it is of critical importance to detect Cu<sup>2+</sup> ions in a highly sensitive and specific way owing to their wide distribution in many physiological processes. Herein, an interesting fluorescence sensing platform was designed for the specific detection of copper ions (Cu<sup>2+</sup>) with excellent photobleaching resistance. In this matter, a dual-emission ratiometric fluorescence sensor was fabricated based on SBA-15-grafted 2-naphthalenemethanol group (2-NM) as a signal reference and zinc sulfide quantum dots (ZnS QDs) as a response, greatly improving experiment accuracy. After adding various metal ions, the fluorescence intensity of 2-NM almost remained unchanged. In contrast, the fluorescence intensity of ZnS QDs indicated the highest response toward Cu<sup>2+</sup> among metal cations. Upon the addition of Cu<sup>2+</sup> ions, the sensor presented a 5-fold fluorescence intensity change (I<sub>320</sub>/I<sub>430</sub>), suggesting that the sensor can be used to detect Cu<sup>2+</sup> with high sensitivity. The level of Cu<sup>2+</sup> can be measured within a wide linear range from 1.0 to 10.0 µmol L<sup>− 1</sup> with a sensitive detection limit of 37.5 nM and a quick sample-to-answer monitoring time of 3&#xa0;min, which is quite certified for regularly monitoring Cu<sup>2+</sup>. Additionally, the developed method could be applied to the efficient quantification of Cu<sup>2+</sup> in practical samples. The presented strategy provides a convenient system for detecting various metal ions in biological activity with high selectivity and good bio-compatibility.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Ratiometric fluorescence sensor for Cu2+ detection based on opposite responses of two fluorescence reagents to SBA-15 substrate

  • Maryam Nouri,
  • Leila Hajiaghababaei,
  • Alireza Badiei,
  • Faezeh Khalilian,
  • Ali Mazloomifar

摘要

One of the many environmental contamination issues around the world is the safer detection or sensing of heavy metal ions. Between all metal ions, it is of critical importance to detect Cu2+ ions in a highly sensitive and specific way owing to their wide distribution in many physiological processes. Herein, an interesting fluorescence sensing platform was designed for the specific detection of copper ions (Cu2+) with excellent photobleaching resistance. In this matter, a dual-emission ratiometric fluorescence sensor was fabricated based on SBA-15-grafted 2-naphthalenemethanol group (2-NM) as a signal reference and zinc sulfide quantum dots (ZnS QDs) as a response, greatly improving experiment accuracy. After adding various metal ions, the fluorescence intensity of 2-NM almost remained unchanged. In contrast, the fluorescence intensity of ZnS QDs indicated the highest response toward Cu2+ among metal cations. Upon the addition of Cu2+ ions, the sensor presented a 5-fold fluorescence intensity change (I320/I430), suggesting that the sensor can be used to detect Cu2+ with high sensitivity. The level of Cu2+ can be measured within a wide linear range from 1.0 to 10.0 µmol L− 1 with a sensitive detection limit of 37.5 nM and a quick sample-to-answer monitoring time of 3 min, which is quite certified for regularly monitoring Cu2+. Additionally, the developed method could be applied to the efficient quantification of Cu2+ in practical samples. The presented strategy provides a convenient system for detecting various metal ions in biological activity with high selectivity and good bio-compatibility.