<p>Digital variance angiography (DVA) exhibits promising prospects with respect to radiation exposure in digital subtraction angiography (DSA). This study aimed to determine the reduction of radiation dose in endovascular peripheral interventions (EPI) using DVA. The DVA imaging tool v6.0 (Kinepict Medical Imaging Tool, version 6.0.4, Kinepict Health Ltd., Budapest, Hungary) was utilized for patients undergoing EPI using digital angiography. EPI normal dose (EPI-ND) protocols were adapted from 1.20 to 0.81 µGy/frame to EPI low dose (EPI-LD) protocols using DVA-LD acquisitions with 0.36 µGy/frame and occasionally 0.24 µGy/frame based on specific examination requirements. The dose area product (DAP) was evaluated and contrast-to-noise ratio (CNR) was measured for each DSA acquisition. Evaluation included 370 EPI-ND and 62 EPI-LD using DVA-LD of three lower extremity regions (mean age: 73 ± 11 years, 67% male). LD protocols decreased median DAP of ND protocols significantly by 62.0% in pelvic, 53.8% in femoral and popliteal, and 59.4% in cruro-pedal regions, respectively (<i>p</i> &lt; .005). DVA-LD increased median CNR significantly compared to DSA-LD (<i>p</i> &lt; .001), and was equal to DSA-ND (<i>p</i> &gt; .15). Image quality was enhanced by CNR<sub>DVA−LD</sub>/CNR<sub>DSA−ND</sub> ratio of 1.9 in pelvic, 2.4 in femoral and popliteal and in cruro-pedal regions. DVA reveals significant radiation dose reduction in lower extremity EPIs and enhances image contrast while decreasing noise.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Radiation exposure reduction in peripheral interventions using digital variance angiography versus conventional angiography

  • Till Schürmann,
  • Ulrich Beschorner,
  • Dirk Westermann,
  • Thomas Zeller,
  • Fabian Bamberg,
  • Christopher L. Schlett,
  • Thomas Stein,
  • Elias Noory

摘要

Digital variance angiography (DVA) exhibits promising prospects with respect to radiation exposure in digital subtraction angiography (DSA). This study aimed to determine the reduction of radiation dose in endovascular peripheral interventions (EPI) using DVA. The DVA imaging tool v6.0 (Kinepict Medical Imaging Tool, version 6.0.4, Kinepict Health Ltd., Budapest, Hungary) was utilized for patients undergoing EPI using digital angiography. EPI normal dose (EPI-ND) protocols were adapted from 1.20 to 0.81 µGy/frame to EPI low dose (EPI-LD) protocols using DVA-LD acquisitions with 0.36 µGy/frame and occasionally 0.24 µGy/frame based on specific examination requirements. The dose area product (DAP) was evaluated and contrast-to-noise ratio (CNR) was measured for each DSA acquisition. Evaluation included 370 EPI-ND and 62 EPI-LD using DVA-LD of three lower extremity regions (mean age: 73 ± 11 years, 67% male). LD protocols decreased median DAP of ND protocols significantly by 62.0% in pelvic, 53.8% in femoral and popliteal, and 59.4% in cruro-pedal regions, respectively (p < .005). DVA-LD increased median CNR significantly compared to DSA-LD (p < .001), and was equal to DSA-ND (p > .15). Image quality was enhanced by CNRDVA−LD/CNRDSA−ND ratio of 1.9 in pelvic, 2.4 in femoral and popliteal and in cruro-pedal regions. DVA reveals significant radiation dose reduction in lower extremity EPIs and enhances image contrast while decreasing noise.