<p>A key innovation of this study is the first-ever experimental determination of the ratio of permanent to total differential pressure loss (Δp<sub>loss</sub>/Δp) for a segmented orifice with an inclined inflow plane—a geometry not standardized in any current measurement norms. While previous investigations by the authors focused on flow characteristics, this paper uniquely quantifies energy-related pressure losses, showing that a 60° inclination reduces permanent pressure loss by up to 4.9% compared to conventional 90° orifices. A combined experimental and numerical approach was applied to evaluate three orifice geometries with water as the working fluid. CFD simulations using the Transition SST model guided the optimization of pressure tapping locations. The results indicate that the inclined design improves flow stability and measurement reliability while reducing pressure losses. The findings suggest that the segmented inclined orifice is a cost-effective and energy-efficient alternative to conventional differential pressure flowmeters in industrial applications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Determination of the constant pressure loss for a new segmented orifice with an inclined inflow plane

  • Marcin Heronimczak,
  • Andrzej Mrowiec,
  • Mariusz Rząsa,
  • Krzysztof Koszela,
  • Piotr Nowaczyk

摘要

A key innovation of this study is the first-ever experimental determination of the ratio of permanent to total differential pressure loss (Δploss/Δp) for a segmented orifice with an inclined inflow plane—a geometry not standardized in any current measurement norms. While previous investigations by the authors focused on flow characteristics, this paper uniquely quantifies energy-related pressure losses, showing that a 60° inclination reduces permanent pressure loss by up to 4.9% compared to conventional 90° orifices. A combined experimental and numerical approach was applied to evaluate three orifice geometries with water as the working fluid. CFD simulations using the Transition SST model guided the optimization of pressure tapping locations. The results indicate that the inclined design improves flow stability and measurement reliability while reducing pressure losses. The findings suggest that the segmented inclined orifice is a cost-effective and energy-efficient alternative to conventional differential pressure flowmeters in industrial applications.