<p>Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas’ tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq1.gif" Format="GIF" Height="14" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(D\)</EquationSource> </InlineEquation>. Patients with bicuspid aortic valves were more sensitive to age, had stronger aortas and required more <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq2.gif" Format="GIF" Height="14" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(D\)</EquationSource> </InlineEquation> than tricuspid valves individuals (peak load: axial loading 4.42 <InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq3.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 1.56 N vs 2.51 <InlineEquation ID="IEq4"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq4.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 1.60 N; circumferential loading 5.76 <InlineEquation ID="IEq5"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq5.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 2.43 N vs 4.82 <InlineEquation ID="IEq6"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq6.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 1.49 N. Fracture energy: axial loading 1.92 <InlineEquation ID="IEq7"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq7.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 0.60 kJ m<sup>-2</sup> vs 0.74 <InlineEquation ID="IEq8"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq8.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 0.50 kJ m<sup>-2</sup>; circumferential loading 2.12 <InlineEquation ID="IEq9"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq9.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 2.39 kJ m<sup>-2</sup> vs 1.47 <InlineEquation ID="IEq10"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq10.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\pm\)</EquationSource> </InlineEquation> 0.91 kJ m<sup>-2</sup>). Collagen content partly explained the variability in <InlineEquation ID="IEq11"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="41598_2024_83233_Article_IEq11.gif" Format="GIF" Height="14" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(D\)</EquationSource> </InlineEquation>, especially in bicuspid cases. Besides the primary crack, TAAs and enzymatic-treated porcine aortas displayed diffuse and shear-dominated dissection and tearing. As human tissue tests resembled enzymatic-treated porcine aortas, microstructural degeneration, including elastin loss and collagen degeneration, seems to be the main cause of TAA wall weakening. Additionally, a tortuous crack developing during the symconCT test reflected intact fracture toughening mechanisms and might characterize a healthier aorta.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Fracture properties of porcine versus human thoracic aortas from tricuspid/bicuspid aortic valve patients via symmetry-constraint Compact Tension testing

  • Marta Alloisio,
  • Antti Siika,
  • David Freiholtz,
  • Anders Franco-Cereceda,
  • Joy Roy,
  • Hanna M. Björck,
  • T. Christian Gasser

摘要

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas’ tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy \(D\) . Patients with bicuspid aortic valves were more sensitive to age, had stronger aortas and required more \(D\) than tricuspid valves individuals (peak load: axial loading 4.42 \(\pm\) 1.56 N vs 2.51 \(\pm\) 1.60 N; circumferential loading 5.76 \(\pm\) 2.43 N vs 4.82 \(\pm\) 1.49 N. Fracture energy: axial loading 1.92 \(\pm\) 0.60 kJ m-2 vs 0.74 \(\pm\) 0.50 kJ m-2; circumferential loading 2.12 \(\pm\) 2.39 kJ m-2 vs 1.47 \(\pm\) 0.91 kJ m-2). Collagen content partly explained the variability in \(D\) , especially in bicuspid cases. Besides the primary crack, TAAs and enzymatic-treated porcine aortas displayed diffuse and shear-dominated dissection and tearing. As human tissue tests resembled enzymatic-treated porcine aortas, microstructural degeneration, including elastin loss and collagen degeneration, seems to be the main cause of TAA wall weakening. Additionally, a tortuous crack developing during the symconCT test reflected intact fracture toughening mechanisms and might characterize a healthier aorta.