<p>The practical application of electrochemical carbon dioxide reduction reaction (CO<sub>2</sub>RR) technology remains hindered by poor stability, primarily owing to bicarbonate salt formation at the cathode, which blocks reactant CO<sub>2</sub> mass flow. Here, using operando characterization tools, we tracked the salt formation process and quantified salt precipitation under varying device operational conditions, elucidating a potential mechanism and optimizing anolyte conditions for long-term (&gt;1,000 h) operation CO<sub>2</sub>RR to CO under &gt;100 mA cm<sup>–2</sup>. Liquid droplets carrying cations and (bi)carbonate ions were observed to migrate from the catalyst/membrane interface towards the backside of the gas diffusion electrode, driven by interfacial gas evolution and CO<sub>2</sub> flow. These droplets eventually dried, forming bicarbonate salt precipitates that blocked the gas flow channels. On the basis of this observation, we applied a hydrophobic parylene coating to the cathode gas flow channel surface, facilitating the removal of the droplets and extending stability from ~100 h to over 500 h under 200 mA cm<sup>–2</sup>.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Improving the operational stability of electrochemical CO2 reduction reaction via salt precipitation understanding and management

  • Shaoyun Hao,
  • Ahmad Elgazzar,
  • Nandakishore Ravi,
  • Tae-Ung Wi,
  • Peng Zhu,
  • Yuge Feng,
  • Yang Xia,
  • Feng-Yang Chen,
  • Xiaonan Shan,
  • Haotian Wang

摘要

The practical application of electrochemical carbon dioxide reduction reaction (CO2RR) technology remains hindered by poor stability, primarily owing to bicarbonate salt formation at the cathode, which blocks reactant CO2 mass flow. Here, using operando characterization tools, we tracked the salt formation process and quantified salt precipitation under varying device operational conditions, elucidating a potential mechanism and optimizing anolyte conditions for long-term (>1,000 h) operation CO2RR to CO under >100 mA cm–2. Liquid droplets carrying cations and (bi)carbonate ions were observed to migrate from the catalyst/membrane interface towards the backside of the gas diffusion electrode, driven by interfacial gas evolution and CO2 flow. These droplets eventually dried, forming bicarbonate salt precipitates that blocked the gas flow channels. On the basis of this observation, we applied a hydrophobic parylene coating to the cathode gas flow channel surface, facilitating the removal of the droplets and extending stability from ~100 h to over 500 h under 200 mA cm–2.