<p>A rapid energy transition will require new heat transfer fluids, and a faster means of discovering and optimizing them. Existing methods, however, are constrained by speed, accuracy, and sample volume — with accurate measurements requiring large sample volumes and long equilibration times. Here, we present a measurement approach that bypasses precise temperature measurement and heat flux measurements. Thermal conductivity, <i>k</i>, is determined by comparing thermally driven voltage variations across an array of resistive heaters embedded in fluid cavities. This measurement, relative to the reference material, minimizes errors from ambient temperature fluctuation, unquantified heat losses, and measurement uncertainties, and it eliminates direct temperature sensing. We report a microfluidic device and measurement method that implements in-run on-chip auto-calibration with a reference material; we test the device on a wide range of substances, including liquids, gases, mixtures, and nanofluids. It delivers results in &lt;10 s, using ~5 µL of sample, about two orders of magnitude faster than conventional steady-state methods — while maintaining accuracy competitive with gold-standard techniques (mean signed error 0.0030 ± 0.0059 W/(m · K) (1.4% ± 3.1%), median absolute error 0.0019 W/(m · K) (MAPE 2.6 %), and expanded uncertainty of <i>k</i>, <i>U</i> = 8.3% ± 0.24% (SD across 10 runs)). This approach makes thermal conductivity measurement accessible to accelerated materials discovery and optimization workflows.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Accurate and rapid measurement of fluid thermal conductivity

  • Amin Kazemi,
  • Mohammad Zargartalebi,
  • David Sinton

摘要

A rapid energy transition will require new heat transfer fluids, and a faster means of discovering and optimizing them. Existing methods, however, are constrained by speed, accuracy, and sample volume — with accurate measurements requiring large sample volumes and long equilibration times. Here, we present a measurement approach that bypasses precise temperature measurement and heat flux measurements. Thermal conductivity, k, is determined by comparing thermally driven voltage variations across an array of resistive heaters embedded in fluid cavities. This measurement, relative to the reference material, minimizes errors from ambient temperature fluctuation, unquantified heat losses, and measurement uncertainties, and it eliminates direct temperature sensing. We report a microfluidic device and measurement method that implements in-run on-chip auto-calibration with a reference material; we test the device on a wide range of substances, including liquids, gases, mixtures, and nanofluids. It delivers results in <10 s, using ~5 µL of sample, about two orders of magnitude faster than conventional steady-state methods — while maintaining accuracy competitive with gold-standard techniques (mean signed error 0.0030 ± 0.0059 W/(m · K) (1.4% ± 3.1%), median absolute error 0.0019 W/(m · K) (MAPE 2.6 %), and expanded uncertainty of k, U = 8.3% ± 0.24% (SD across 10 runs)). This approach makes thermal conductivity measurement accessible to accelerated materials discovery and optimization workflows.