<p>Modern thermoelectric modules have emerged as promising platforms for precision thermal analysis in biological and chemical applications. This study presents a high-throughput microcalorimeter employing a patterned bismuth telluride (Bi<sub>2</sub>Te<sub>3</sub>) thermopile array as integrated heat flux sensors, overcoming the throughput limitations of conventional calorimetric systems. Through finite element analysis-guided device optimization, we established that increasing thermocouple height from 0.4 mm to 0.8 mm reduces thermal conductance, achieving around 1 <InlineEquation ID="IEq1"> <EquationSource Format="TEX">\({\rm{V}}\cdot {{\rm{W}}}^{-1}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mi mathvariant="normal">V</mi> <mo>·</mo> <msup> <mrow> <mi mathvariant="normal">W</mi> </mrow> <mrow> <mo>−</mo> <mn>1</mn> </mrow> </msup> </mrow> </math></EquationSource> </InlineEquation> power sensitivity. The system demonstrated dual-mode calibration methods using both the electrical (Joule heating) and the chemical (water-ethanol mixing enthalpy) references. Device functionality was validated through real-time monitoring of <i>Escherichia coli</i> metabolism, revealing distinct thermal signatures upon antibiotic challenge. The antimicrobial susceptibility testing (AST) is performed with 4 commonly used antibiotics. The platform achieved 4 h AST with coherent values to Clinical and Laboratory Standards Institute (CLSI) guidelines for minimum inhibitory concentration (MIC) determination. Notably, the modular chip architecture integrates 8 sensing units as a proof-of-concept, coupled with disposable microfluidic chambers that eliminate cross-contamination risks. This chip-calorimeter implementation establishes a new paradigm for chemical reaction heat measurement and rapid clinical diagnostics of infectious diseases.</p><p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

High-throughput chip-calorimeter using a Bi2Te3 thermopile heat flux sensor array

  • Yang Liu,
  • Zhengguang Chen,
  • Yushan Xie,
  • Yinghao Zhang,
  • Guanqin Zhang,
  • Yuchen Wang,
  • Jiale Cheng

摘要

Modern thermoelectric modules have emerged as promising platforms for precision thermal analysis in biological and chemical applications. This study presents a high-throughput microcalorimeter employing a patterned bismuth telluride (Bi2Te3) thermopile array as integrated heat flux sensors, overcoming the throughput limitations of conventional calorimetric systems. Through finite element analysis-guided device optimization, we established that increasing thermocouple height from 0.4 mm to 0.8 mm reduces thermal conductance, achieving around 1 \({\rm{V}}\cdot {{\rm{W}}}^{-1}\) V · W 1 power sensitivity. The system demonstrated dual-mode calibration methods using both the electrical (Joule heating) and the chemical (water-ethanol mixing enthalpy) references. Device functionality was validated through real-time monitoring of Escherichia coli metabolism, revealing distinct thermal signatures upon antibiotic challenge. The antimicrobial susceptibility testing (AST) is performed with 4 commonly used antibiotics. The platform achieved 4 h AST with coherent values to Clinical and Laboratory Standards Institute (CLSI) guidelines for minimum inhibitory concentration (MIC) determination. Notably, the modular chip architecture integrates 8 sensing units as a proof-of-concept, coupled with disposable microfluidic chambers that eliminate cross-contamination risks. This chip-calorimeter implementation establishes a new paradigm for chemical reaction heat measurement and rapid clinical diagnostics of infectious diseases.