<p>Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the artificial structuring of scintillators offer new opportunities for improving the energy resolution of scintillator-based X-ray detectors. Here, we present a three-bin energy-resolved X-ray imaging framework based on a three-layer multicolor scintillator used in conjunction with a physics-aware image postprocessing algorithm. The multicolor scintillator is able to preserve X-ray energy information through the combination of emission wavelength multiplexing and energy-dependent isolation of X-ray absorption in specific layers. The dominant emission color and the radius of the spot measured by the detector are used to infer the incident X-ray energy based on prior knowledge of the energy-dependent absorption profiles of the scintillator stack. Through ab initio Monte Carlo simulations, we show that our approach can achieve an energy reconstruction accuracy of 49.7%, which is only 2% below the maximum accuracy achievable with realistic scintillators. We apply our framework to medical phantom imaging simulations where we demonstrate that it can effectively differentiate iodine and gadolinium-based contrast agents from bone, muscle, and soft tissue.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

End-to-end design of multicolor scintillators for enhanced energy resolution in X-ray imaging

  • Seokhwan Min,
  • Seou Choi,
  • Simo Pajovic,
  • Sachin Vaidya,
  • Nicholas Rivera,
  • Shanhui Fan,
  • Marin Soljačić,
  • Charles Roques-Carmes

摘要

Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the artificial structuring of scintillators offer new opportunities for improving the energy resolution of scintillator-based X-ray detectors. Here, we present a three-bin energy-resolved X-ray imaging framework based on a three-layer multicolor scintillator used in conjunction with a physics-aware image postprocessing algorithm. The multicolor scintillator is able to preserve X-ray energy information through the combination of emission wavelength multiplexing and energy-dependent isolation of X-ray absorption in specific layers. The dominant emission color and the radius of the spot measured by the detector are used to infer the incident X-ray energy based on prior knowledge of the energy-dependent absorption profiles of the scintillator stack. Through ab initio Monte Carlo simulations, we show that our approach can achieve an energy reconstruction accuracy of 49.7%, which is only 2% below the maximum accuracy achievable with realistic scintillators. We apply our framework to medical phantom imaging simulations where we demonstrate that it can effectively differentiate iodine and gadolinium-based contrast agents from bone, muscle, and soft tissue.