<p>As one of the most harmful heavy metal pollutants, hexavalent chromium Cr(VI) is becoming a serious threat to human health. Thus pursuing a remarkably sensitive method to monitor the Cr(VI) concentration in natural conditions is favored for the fast response to prevent harm. In the present work, an ethylenediamine (En) and SiO<sub>2</sub>-modified wool keratin-based carbon quantum dot (CQD)(En@CQDs@SiO<sub>2</sub>) fluorescent sensor is prepared, and the En is found to improve the discrimination ability by binding the Cr(VI) with the surface carboxyl groups. Based on these designs, the En@CQDs@SiO<sub>2</sub> achieves a significant improvement in the Cr(VI) detection ability, with a detection limit of 6.08 × 10<sup>–4</sup>&#xa0;mg/L, which succeeded 6 times over CQDs, and is better than conventional UV–Vis and flame atomic absorption (AAS) techniques. Furthermore, the fluorescent sensor has good relative sensitivity, selectivity, good spectral reproducibility, and excellent structural stability. These properties make the sensor suitable for environmental Cr(VI) detection, which undoubtedly improves the economy and environmental friendliness of the fluorescent sensor.</p> Graphical abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Surface-modified carbon quantum dot for enhanced fluorescent-sensing of hexagonal valent chromium

  • Kangle Shang,
  • Hansong Chen,
  • Wenwen Yang,
  • Yucheng He,
  • Baoyi Liu,
  • Xuxin Yi,
  • Xiaoli Tan,
  • Ming Fang

摘要

As one of the most harmful heavy metal pollutants, hexavalent chromium Cr(VI) is becoming a serious threat to human health. Thus pursuing a remarkably sensitive method to monitor the Cr(VI) concentration in natural conditions is favored for the fast response to prevent harm. In the present work, an ethylenediamine (En) and SiO2-modified wool keratin-based carbon quantum dot (CQD)(En@CQDs@SiO2) fluorescent sensor is prepared, and the En is found to improve the discrimination ability by binding the Cr(VI) with the surface carboxyl groups. Based on these designs, the En@CQDs@SiO2 achieves a significant improvement in the Cr(VI) detection ability, with a detection limit of 6.08 × 10–4 mg/L, which succeeded 6 times over CQDs, and is better than conventional UV–Vis and flame atomic absorption (AAS) techniques. Furthermore, the fluorescent sensor has good relative sensitivity, selectivity, good spectral reproducibility, and excellent structural stability. These properties make the sensor suitable for environmental Cr(VI) detection, which undoubtedly improves the economy and environmental friendliness of the fluorescent sensor.

Graphical abstract