<p>This research developed a highly efficient voltammetric sensor, utilizing a carbon paste electrode (CPE) integrated with a novel ZnO-doped Pd–Pt bimetallic catalyst decorated with reduced graphene oxide (ZnO-Pt@Pd/rGO) and 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([EMIM][Tf2N]), for the precise determination of sulfafurazole in real dextrose saline and tablet samples. The ZnO-Pt@Pd/rGO nanocomposite was synthesized through a one-stage synthesis process and characterized using SEM and EDS techniques. The comparison of the ZnO-Pt@Pd/rGO/[EMIM][Tf2N]/CPE with unmodified CPE, ZnO-Pt@Pd/rGO/CPE, and [EMIM][Tf2N]/CPE confirms the synergic effect of ZnO-Pt@Pd/rGO and [EMIM][Tf2N] as two conductive catalysts in fabrication of new sensor. The resulting sensor exhibited remarkable stability over a period of 2 months without compromising its efficiency for sulfafurazole detection. With a linear range of 0.001–250 µM (<i>R</i><sup>2</sup> = 0.9971) and LOD of 0.4 nM, ZnO-Pt@Pd/rGO/[EMIM][Tf2N]/CPE showcased exceptional accuracy and precision in the monitoring of sulfafurazole. Validation using real tablet and dextrose saline samples confirmed the sensor's outstanding capability in determining sulfafurazole, with relative recoveries ranging from 98.92 to 103.8% offering a promising solution for reliable sulfafurazole analysis in diverse pharmaceutical samples.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Development of a graphene-based bimetallic catalyst for enhanced voltammetric detection of sulfafurazole antimicrobial agents

  • Mohammad Khazaei Nejad,
  • Hassan Ali Zamani

摘要

This research developed a highly efficient voltammetric sensor, utilizing a carbon paste electrode (CPE) integrated with a novel ZnO-doped Pd–Pt bimetallic catalyst decorated with reduced graphene oxide (ZnO-Pt@Pd/rGO) and 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([EMIM][Tf2N]), for the precise determination of sulfafurazole in real dextrose saline and tablet samples. The ZnO-Pt@Pd/rGO nanocomposite was synthesized through a one-stage synthesis process and characterized using SEM and EDS techniques. The comparison of the ZnO-Pt@Pd/rGO/[EMIM][Tf2N]/CPE with unmodified CPE, ZnO-Pt@Pd/rGO/CPE, and [EMIM][Tf2N]/CPE confirms the synergic effect of ZnO-Pt@Pd/rGO and [EMIM][Tf2N] as two conductive catalysts in fabrication of new sensor. The resulting sensor exhibited remarkable stability over a period of 2 months without compromising its efficiency for sulfafurazole detection. With a linear range of 0.001–250 µM (R2 = 0.9971) and LOD of 0.4 nM, ZnO-Pt@Pd/rGO/[EMIM][Tf2N]/CPE showcased exceptional accuracy and precision in the monitoring of sulfafurazole. Validation using real tablet and dextrose saline samples confirmed the sensor's outstanding capability in determining sulfafurazole, with relative recoveries ranging from 98.92 to 103.8% offering a promising solution for reliable sulfafurazole analysis in diverse pharmaceutical samples.