<p>This study presents an automated drop-casting deposition method implemented by modifying a micropipette for motor-controlled operation using an interface developed in MATLAB. The system was optimized to deliver precise 2 µL droplets, ensuring uniform film deposition on quartz crystal microbalance (QCM) electrodes. Compared to manual deposition, the automated method showed significant improvements in film surface roughness and thickness uniformity, achieving 2.5 to 3.3 times lower standard deviations in film thickness and up to a 60% reduction in thickness dispersion. Atomic force microscopy (AFM) analysis showed a 3.5 times reduction in surface roughness dispersion for Poly (methyl methacrylate) (PMMA) films. Statistical analysis using F-tests confirmed the improvement in thickness uniformity for Apiezon L (p = 0.02102), PMMA (p = 0.00283) and ethyl cellulose (p = 0.00120) films. These results highlight the better control provided by the automated system, leading to enhanced gas sensor performance with sensitivity increments up to 30% when exposed to 2130&#xa0;ppm of heptane and 2060&#xa0;ppm of ethanol concentrations.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Automation of the drop-casting deposition method for polymeric sensing films over a quartz crystal microbalance

  • Alexis Iván Bravo-Sánchez,
  • Juan Castillo-Mixcóatl,
  • Miguel Ángel Moreno-Acosta,
  • Omar Sosa-Ramos,
  • Marcos Rodríguez-Torres,
  • Georgina Beltrán-Pérez,
  • Víctor Altuzar,
  • Claudia Mendoza-Barrera,
  • Severino Muñoz-Aguirre

摘要

This study presents an automated drop-casting deposition method implemented by modifying a micropipette for motor-controlled operation using an interface developed in MATLAB. The system was optimized to deliver precise 2 µL droplets, ensuring uniform film deposition on quartz crystal microbalance (QCM) electrodes. Compared to manual deposition, the automated method showed significant improvements in film surface roughness and thickness uniformity, achieving 2.5 to 3.3 times lower standard deviations in film thickness and up to a 60% reduction in thickness dispersion. Atomic force microscopy (AFM) analysis showed a 3.5 times reduction in surface roughness dispersion for Poly (methyl methacrylate) (PMMA) films. Statistical analysis using F-tests confirmed the improvement in thickness uniformity for Apiezon L (p = 0.02102), PMMA (p = 0.00283) and ethyl cellulose (p = 0.00120) films. These results highlight the better control provided by the automated system, leading to enhanced gas sensor performance with sensitivity increments up to 30% when exposed to 2130 ppm of heptane and 2060 ppm of ethanol concentrations.