<p>This study evaluated the feasibility and safety of Synchroseal (SS), a new articulating bipolar energy-based device, in da Vinci robotic gastrectomy for gastric cancer. A prospective study of 25 patients using SS was compared with retrospective data from 218 patients treated with conventional ultrasonic shears (US). Propensity score matching (PSM) ensured comparability. Metrics analyzed included C-reactive protein (CRP) levels, operative time, lymph nodes (LNs) retrieved, intraoperative blood loss, laboratory tests, hospital stay duration, and complication rates. PSM yielded a balanced comparison between the two groups (standardized differences &lt; 0.1). SS (<i>n</i> = 25) significantly reduced CRP levels on postoperative days 2, 4, and 6 compared to US (<i>n</i> = 123) [7.67 ± 4.73 vs. 10.18 ± 5.66, (<i>p</i> = 0.040), 5.11 ± 3.33 vs. 6.65 ± 4.23, (<i>p</i> = 0.090), 2.74 ± 2.10 vs. 4.26 ± 3.78, (<i>p</i> = 0.001)]. Additionally, SS showed lower serum amylase levels and shorter operation times than US [67.60 ± 48.31 vs. 168.66 ± 316.92, (<i>p</i> = 0.027) and 234.52 ± 65.03 vs. 274.75 ± 54.90, (<i>p</i> = 0.002)]. Although SS retrieved fewer total LNs (31.80 ± 9.5 vs. 36.88 ± 14.96, <i>p</i> = 0.034), both groups achieved adequate LN dissection (&gt; 30 LNs). No significant differences were observed in other parameters. SS led to lower postoperative CRP and serum amylase levels, shorter operation time, and adequate LN dissection, suggesting reduced postoperative inflammation and faster sealing function as potential benefits.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Feasibility and safety of the synchroseal articulating bipolar energy-based device for robotic gastrectomy in patients with gastric cancer: a prospective single-arm clinical trial with historical controls

  • Ji-Hyeon Park,
  • JeeSun Kim,
  • Danbi Lee,
  • Seong-Ho Kong,
  • Do Joong Park,
  • Hyuk-Joon Lee,
  • Han-Kwang Yang

摘要

This study evaluated the feasibility and safety of Synchroseal (SS), a new articulating bipolar energy-based device, in da Vinci robotic gastrectomy for gastric cancer. A prospective study of 25 patients using SS was compared with retrospective data from 218 patients treated with conventional ultrasonic shears (US). Propensity score matching (PSM) ensured comparability. Metrics analyzed included C-reactive protein (CRP) levels, operative time, lymph nodes (LNs) retrieved, intraoperative blood loss, laboratory tests, hospital stay duration, and complication rates. PSM yielded a balanced comparison between the two groups (standardized differences < 0.1). SS (n = 25) significantly reduced CRP levels on postoperative days 2, 4, and 6 compared to US (n = 123) [7.67 ± 4.73 vs. 10.18 ± 5.66, (p = 0.040), 5.11 ± 3.33 vs. 6.65 ± 4.23, (p = 0.090), 2.74 ± 2.10 vs. 4.26 ± 3.78, (p = 0.001)]. Additionally, SS showed lower serum amylase levels and shorter operation times than US [67.60 ± 48.31 vs. 168.66 ± 316.92, (p = 0.027) and 234.52 ± 65.03 vs. 274.75 ± 54.90, (p = 0.002)]. Although SS retrieved fewer total LNs (31.80 ± 9.5 vs. 36.88 ± 14.96, p = 0.034), both groups achieved adequate LN dissection (> 30 LNs). No significant differences were observed in other parameters. SS led to lower postoperative CRP and serum amylase levels, shorter operation time, and adequate LN dissection, suggesting reduced postoperative inflammation and faster sealing function as potential benefits.