<p>In this study, we designed an inflatable soft actuator with a novel pneumatic inflatable exhaust valve to reduce exhausting time. The soft wearable robots using inflatable actuators had limitations in joint movement during exhaus phase due to residual air remaining in the actuators since the exhaust time was long. We proposed the novel pneumatic inflatable exhaust valve by utilizing the pneumatic power transmission to block larger orifices compared with commercial pneumatic valves. Two inflatable layers of the proposed valve were installed at the top and bottom of the actuator layer to cover the large exhaust area. Our actuator’s deflation time was 0.13 seconds using the proposed valves and it was 3.2 times faster than using only a commercial solenoid valve. The −3 dB bandwidth of exhausting air was 4.2 Hz for our actuator. Moreover, the actuator bandwidth was 3.4 Hz from the dynamic response experiment, which was sufficient to cover the human walking frequency. Lastly, we validated our actuator to assist knee movements for ground walking and stair ascending through the developed fully wearable soft knee robot.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Design of an Inflatable Exhaust Valve to Improve Bandwidth of Inflatable Actuators: A Feasibility Study With a Soft Knee Wearable Robot

  • Junghoon Park,
  • Youngjin Na,
  • Jung Kim

摘要

In this study, we designed an inflatable soft actuator with a novel pneumatic inflatable exhaust valve to reduce exhausting time. The soft wearable robots using inflatable actuators had limitations in joint movement during exhaus phase due to residual air remaining in the actuators since the exhaust time was long. We proposed the novel pneumatic inflatable exhaust valve by utilizing the pneumatic power transmission to block larger orifices compared with commercial pneumatic valves. Two inflatable layers of the proposed valve were installed at the top and bottom of the actuator layer to cover the large exhaust area. Our actuator’s deflation time was 0.13 seconds using the proposed valves and it was 3.2 times faster than using only a commercial solenoid valve. The −3 dB bandwidth of exhausting air was 4.2 Hz for our actuator. Moreover, the actuator bandwidth was 3.4 Hz from the dynamic response experiment, which was sufficient to cover the human walking frequency. Lastly, we validated our actuator to assist knee movements for ground walking and stair ascending through the developed fully wearable soft knee robot.