Objective <p>The aim of this study was to compare the diagnostic accuracy of <sup>68</sup>Ga-PSMA-11 PET/CT and multiparametric MRI (mpMRI) in detecting unilateral and bilateral intra-glandular prostate cancer lesions.</p> Methods <p>A retrospective analysis was conducted on 73 prostate cancer patients diagnosed via biopsy, all of whom underwent both <sup>68</sup>Ga-PSMA-11 PET/CT and mpMRI prior to surgery. Two independent readers, blinded to each other’s results and to pathology findings, evaluated the imaging modalities to make a diagnosis of unilateral (left or right) or bilateral lesions for suspected prostate lesions. Histopathological findings from a 12-core transrectal ultrasound-guided biopsy and radical prostatectomy served as reference standards. The accuracy of both imaging modalities in determining unilateral and bilateral intra-glandular prostate cancer was assessed through receiver operating characteristic curve analysis. Additionally, factors influencing diagnostic discordance between the two modalities were evaluated.</p> Results <p>A total of 73 patients were included in the final analysis, comprising 34 with unilateral lesions and 39 with bilateral lesions. Among these, 35 patients underwent radical prostatectomy, revealing 22 cases of bilateral lesions and 13 cases of unilateral lesions [Kappa = 0.76 (<i>P</i> &lt; 0.001)]. The lateral diagnostic accuracy of <sup>68</sup>Ga-PSMA-11 PET/CT, based on pathological results from biopsy or prostatectomy, was 80.82% (59/73) and 82.86% (29/35), respectively. These values were significantly higher than those of mpMRI, which demonstrated an accuracy of 54.79% (40/73, <i>P</i> &lt; 0.001) and 40% (14/35, <i>P</i> &lt; 0.001), respectively. Concordance between <sup>68</sup>Ga-PSMA-11 PET/CT and mpMRI for the lateralization accuracy was poor (kappa = 0.015, <i>P</i> &lt; 0.05). When both imaging modalities provided consistent lateralization results (39/73), concordance with pathological findings reached 87.18% (34/39). However, concordance with pathological results was significantly higher for <sup>68</sup>Ga-PSMA-11 PET/CT (76.47%, 26/34) compared to mpMRI (20.59%, 7/34). Further analysis revealed that an SUVmax &gt; 3.95 for <sup>68</sup>Ga-PSMA-11 PET/CT and a PI-RADS score ≥ 4 for mpMRI were independent factors influencing lateral diagnostic concordance.</p> Conclusion <p>The <sup>68</sup>Ga-PSMA-11 PET/CT demonstrated significantly higher lateralization accuracy than mpMRI in intra-glandular prostate cancer. There was considerable inconsistency in the diagnostic outcomes between <sup>68</sup>Ga-PSMA-11 PET/CT and mpMRI, and in cases of discordance, <sup>68</sup>Ga-PSMA-11 PET/CT was notably more accurate. SUVmax &gt; 3.95 and PI-RADS score ≥ 4 were critical factors influencing the correct lateralization accuracy when the results from <sup>68</sup>Ga-PSMA-11 PET/CT and mpMRI were inconsistent.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Superiority of 68Ga-PSMA-11 PET/CT over mpMRI for lateralization accuracy of diagnosing intra-glandular prostate cancer lesions: avoiding fluke targeting

  • Min Wang,
  • Zhiyong Quan,
  • Keke Xin,
  • Guiyu Li,
  • Taoqi Ma,
  • Junling Wang,
  • Weijun Qin,
  • Jing Wang,
  • Fei Kang

摘要

Objective

The aim of this study was to compare the diagnostic accuracy of 68Ga-PSMA-11 PET/CT and multiparametric MRI (mpMRI) in detecting unilateral and bilateral intra-glandular prostate cancer lesions.

Methods

A retrospective analysis was conducted on 73 prostate cancer patients diagnosed via biopsy, all of whom underwent both 68Ga-PSMA-11 PET/CT and mpMRI prior to surgery. Two independent readers, blinded to each other’s results and to pathology findings, evaluated the imaging modalities to make a diagnosis of unilateral (left or right) or bilateral lesions for suspected prostate lesions. Histopathological findings from a 12-core transrectal ultrasound-guided biopsy and radical prostatectomy served as reference standards. The accuracy of both imaging modalities in determining unilateral and bilateral intra-glandular prostate cancer was assessed through receiver operating characteristic curve analysis. Additionally, factors influencing diagnostic discordance between the two modalities were evaluated.

Results

A total of 73 patients were included in the final analysis, comprising 34 with unilateral lesions and 39 with bilateral lesions. Among these, 35 patients underwent radical prostatectomy, revealing 22 cases of bilateral lesions and 13 cases of unilateral lesions [Kappa = 0.76 (P < 0.001)]. The lateral diagnostic accuracy of 68Ga-PSMA-11 PET/CT, based on pathological results from biopsy or prostatectomy, was 80.82% (59/73) and 82.86% (29/35), respectively. These values were significantly higher than those of mpMRI, which demonstrated an accuracy of 54.79% (40/73, P < 0.001) and 40% (14/35, P < 0.001), respectively. Concordance between 68Ga-PSMA-11 PET/CT and mpMRI for the lateralization accuracy was poor (kappa = 0.015, P < 0.05). When both imaging modalities provided consistent lateralization results (39/73), concordance with pathological findings reached 87.18% (34/39). However, concordance with pathological results was significantly higher for 68Ga-PSMA-11 PET/CT (76.47%, 26/34) compared to mpMRI (20.59%, 7/34). Further analysis revealed that an SUVmax > 3.95 for 68Ga-PSMA-11 PET/CT and a PI-RADS score ≥ 4 for mpMRI were independent factors influencing lateral diagnostic concordance.

Conclusion

The 68Ga-PSMA-11 PET/CT demonstrated significantly higher lateralization accuracy than mpMRI in intra-glandular prostate cancer. There was considerable inconsistency in the diagnostic outcomes between 68Ga-PSMA-11 PET/CT and mpMRI, and in cases of discordance, 68Ga-PSMA-11 PET/CT was notably more accurate. SUVmax > 3.95 and PI-RADS score ≥ 4 were critical factors influencing the correct lateralization accuracy when the results from 68Ga-PSMA-11 PET/CT and mpMRI were inconsistent.