Objective <p>Reduction of bleeding and prolonged air leak (&gt;5 days) following major lung resection remains a challenge. Hemostasis and aerostasis devices can facilitate earlier pleural de-drainage and fast-track. Our objectives were to evaluate the efficacy of TenaTac<sup>®</sup> (an elastic, adhering patch approved as a medical device) in reducing bleeding and prolonged air leak after major lung resection.</p> Methods <p>This monocentric retrospective case–control study, using prospectively collected data, includes 60 patients who underwent, between 2022 and 2024, minimally invasive robot-assisted lobectomy or segmentectomy: 30 with TenaTac<sup>®</sup> <i>vs.</i> 30 with other devices. Data were extracted from Epithor, the French national database, with ethics committee validation.</p> Results <p>Patients characteristics, Index of Prolonged Air Leak, and surgical procedures were similar in both groups (NS). TenaTac<sup>®</sup> hemostatic benefit was comparable to other devices (<i>p</i> = 0.56). Prolonged air leak rate was significantly lower with TenaTac<sup>®</sup> (3%) than for control devices (37%) (<i>p</i> = 0.0004). Post-operative air leakage duration was significantly shorter in TenaTac<sup>®</sup> group than in control group (2.23 ± 2.57 <i>vs.</i> 4.23 ± 3.87 days, <i>p</i> = 0.01). Mean drainage duration and length of stay were both reduced with TenaTac<sup>®</sup> by 36 hours. No significant difference was observed between the two groups in terms of morbidity (90-day post-operative complications classified as Clavien–Dindo grade&gt;II, <i>p</i> = 0.33), readmission rates (nil), or 90-day mortality (no deaths).</p> Conclusions <p>Numerous hemostatic or aerostatic devices have been previously evaluated without achieving consensus in the prevention of prolonged air leak. As an absorbable, adherent gelatine patch, TenaTac<sup>®</sup> significantly reduces the incidence of prolonged air leak after major lung resection.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Blood loss and prolonged air leak reduction by applying TenaTac® gelatine patch after major pulmonary minimal-invasive resection

  • Caroline Rivera,
  • Cyril Perrot,
  • Florence Mazeres,
  • Elodie Rive

摘要

Objective

Reduction of bleeding and prolonged air leak (>5 days) following major lung resection remains a challenge. Hemostasis and aerostasis devices can facilitate earlier pleural de-drainage and fast-track. Our objectives were to evaluate the efficacy of TenaTac® (an elastic, adhering patch approved as a medical device) in reducing bleeding and prolonged air leak after major lung resection.

Methods

This monocentric retrospective case–control study, using prospectively collected data, includes 60 patients who underwent, between 2022 and 2024, minimally invasive robot-assisted lobectomy or segmentectomy: 30 with TenaTac® vs. 30 with other devices. Data were extracted from Epithor, the French national database, with ethics committee validation.

Results

Patients characteristics, Index of Prolonged Air Leak, and surgical procedures were similar in both groups (NS). TenaTac® hemostatic benefit was comparable to other devices (p = 0.56). Prolonged air leak rate was significantly lower with TenaTac® (3%) than for control devices (37%) (p = 0.0004). Post-operative air leakage duration was significantly shorter in TenaTac® group than in control group (2.23 ± 2.57 vs. 4.23 ± 3.87 days, p = 0.01). Mean drainage duration and length of stay were both reduced with TenaTac® by 36 hours. No significant difference was observed between the two groups in terms of morbidity (90-day post-operative complications classified as Clavien–Dindo grade>II, p = 0.33), readmission rates (nil), or 90-day mortality (no deaths).

Conclusions

Numerous hemostatic or aerostatic devices have been previously evaluated without achieving consensus in the prevention of prolonged air leak. As an absorbable, adherent gelatine patch, TenaTac® significantly reduces the incidence of prolonged air leak after major lung resection.