<p>Rationale and objectives: Ankylosing spondylitis (AS) is a lifelong form of arthritis that inflames the sacroiliac joints (SIJs) and spine. Compared to magnetic resonance imaging (MRI), computed tomography (CT) better images bony erosions within SIJs - subtle early-stage AS indicators - and CT is considered the “gold standard” AS diagnostic modality. While clinical AS diagnoses via CT yield impressive specificity, sensitivity often lags. Materials and methods: Using 2 000+ SIJs across the pelvic CT scans of 35 AS patients and 65 control patients, a 3-stage computer vision diagnostic pipeline was developed: SIJ localization/extraction using YOLOv5; classifying SIJs as AS (across various progression levels) or control (across young and old age groups) via a custom vision transformer (ViT) + InceptionV3 hybrid architecture; and using aggregated/normalized SIJ classification results to predict AS at the patient level using a traditional machine learning model. Results: For 73 patients with &gt; 8 SIJs (restriction limits the impact of SIJ misclassifications), the proposed pipeline achieved 98.63% accuracy, 96.43% sensitivity, perfect specificity, and 96.51% ROC AUC. It is demonstrated to be robust and outperforms retrained related works. Compared to vanilla ViT for SIJ classification, the hybrid model pipeline is 16% more accurate with 14% higher ROC AUC; compared to vanilla InceptionV3, it is 7% more accurate with 4% higher ROC AUC. Conclusion: AS can be diagnosed with high sensitivity and specificity via the proposed pipeline. ViT + InceptionV3 outperforms its baseline forebears while unifying their respective strengths. Being able to capture global and local details, ViT + InceptionV3 is applicable to tasks within computer assisted diagnostics and elsewhere.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A Novel Vision Transformer + InceptionV3 Hybrid Network for Accurate Diagnosis of Ankylosing Spondylitis from Computed Tomography Scans

  • Riel Castro-Zunti,
  • Eun Hae Park,
  • Amol Satsangi,
  • Younhee Choi,
  • Gong Yong Jin,
  • Hee Suk Chae,
  • Seok-Bum Ko

摘要

Rationale and objectives: Ankylosing spondylitis (AS) is a lifelong form of arthritis that inflames the sacroiliac joints (SIJs) and spine. Compared to magnetic resonance imaging (MRI), computed tomography (CT) better images bony erosions within SIJs - subtle early-stage AS indicators - and CT is considered the “gold standard” AS diagnostic modality. While clinical AS diagnoses via CT yield impressive specificity, sensitivity often lags. Materials and methods: Using 2 000+ SIJs across the pelvic CT scans of 35 AS patients and 65 control patients, a 3-stage computer vision diagnostic pipeline was developed: SIJ localization/extraction using YOLOv5; classifying SIJs as AS (across various progression levels) or control (across young and old age groups) via a custom vision transformer (ViT) + InceptionV3 hybrid architecture; and using aggregated/normalized SIJ classification results to predict AS at the patient level using a traditional machine learning model. Results: For 73 patients with > 8 SIJs (restriction limits the impact of SIJ misclassifications), the proposed pipeline achieved 98.63% accuracy, 96.43% sensitivity, perfect specificity, and 96.51% ROC AUC. It is demonstrated to be robust and outperforms retrained related works. Compared to vanilla ViT for SIJ classification, the hybrid model pipeline is 16% more accurate with 14% higher ROC AUC; compared to vanilla InceptionV3, it is 7% more accurate with 4% higher ROC AUC. Conclusion: AS can be diagnosed with high sensitivity and specificity via the proposed pipeline. ViT + InceptionV3 outperforms its baseline forebears while unifying their respective strengths. Being able to capture global and local details, ViT + InceptionV3 is applicable to tasks within computer assisted diagnostics and elsewhere.