Purpose <p>N-butyl-2-cyanoacrylate (NBCA) and Lipiodol mixture (NL) are widely used for emergency embolization due to their effective polymerization upon contact with blood. However, NBCA’s strong adhesive properties can cause complications, leading to the development of an NBCA-Lipiodol-ethanol mixture (NLE), which has shown reduced catheter adhesion. This study aimed to observe the structural differences between NL and NLE polymers using scanning electron microscopy.</p> Materials and methods <p>Four different ratios of NBCA, Lipiodol, and ethanol (NLE230, NLE221, NLE150, and NLE141) were examined. The samples were injected into silicone tubes filled with human serum, and the polymerized specimens were collected and observed using scanning electron microscopy.</p> Results <p>NLE230 formed a dense, three-dimensional honeycomb-like structure, whereas NLE221 exhibited a two-dimensional folded-sheet structure. Both NLE150 and NLE141 exhibited a folded-sheet structure; however, NLE141 was considerably more fragile, with cracks and rough surfaces, resulting in a structure that lacked uniformity.</p> Conclusion <p>The differences in structure suggest that ethanol considerably influences the polymerization process. These differences may explain characteristics of NLE, such as low adhesion.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Structural comparison of N-butyl-2-cyanoacrylate-Lipiodol (NL) and N-butyl-2-cyanoacrylate-Lipiodol-Ethanol (NLE) using scanning electron microscope

  • Yu Sasaki,
  • Takuji Araki,
  • Munetsugu Ban,
  • Kodai Hujihara,
  • Hiroto Imaimatsu,
  • Hiroki Okada,
  • Toshiyuki Oda,
  • Hiroshi Onishi

摘要

Purpose

N-butyl-2-cyanoacrylate (NBCA) and Lipiodol mixture (NL) are widely used for emergency embolization due to their effective polymerization upon contact with blood. However, NBCA’s strong adhesive properties can cause complications, leading to the development of an NBCA-Lipiodol-ethanol mixture (NLE), which has shown reduced catheter adhesion. This study aimed to observe the structural differences between NL and NLE polymers using scanning electron microscopy.

Materials and methods

Four different ratios of NBCA, Lipiodol, and ethanol (NLE230, NLE221, NLE150, and NLE141) were examined. The samples were injected into silicone tubes filled with human serum, and the polymerized specimens were collected and observed using scanning electron microscopy.

Results

NLE230 formed a dense, three-dimensional honeycomb-like structure, whereas NLE221 exhibited a two-dimensional folded-sheet structure. Both NLE150 and NLE141 exhibited a folded-sheet structure; however, NLE141 was considerably more fragile, with cracks and rough surfaces, resulting in a structure that lacked uniformity.

Conclusion