<p>A model for the dynamic pressure loss in standard oleo-pneumatic shock absorbers without gas-oil separator for avionics applications is introduced. The dynamics of such a device under load variations are primarily determined by the throttle between the oil chamber and the gas chamber. During operation, gas is absorbed by the oil upon compression and desorbed upon expansion, which are processes that extend over time and entail hysteresis. It is found that the assumption of isothermal conditions is sufficient. An excellent alignment is achieved by the model and the measured hysteresis across diverse drop test scenarios, adjusting a single parameter to a value that is physically reasonable. The standard deviation of the error in pressure is <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11071_2025_10947_Article_IEq1.gif" Format="GIF" Height="19" Rendition="HTML" Resolution="72" Type="Linedraw" Width="94" /> </InlineMediaObject> <EquationSource Format="TEX">\({\sigma _{p}=0.49\,\textrm{bar}}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <msub> <mi>σ</mi> <mi>p</mi> </msub> <mo>=</mo> <mn>0.49</mn> <mspace width="0.166667em" /> <mtext>bar</mtext> </mrow> </math></EquationSource> </InlineEquation>. Moreover, the model rests on thermodynamic considerations and experimental gas solubility data, while it is consistent with other laboratory data from the literature.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Modeling dynamic pressure loss by absorption in oleo-pneumatic shock absorbers without separator

  • Felix Willich,
  • Florian Holzapfel,
  • Jadran Vrabec

摘要

A model for the dynamic pressure loss in standard oleo-pneumatic shock absorbers without gas-oil separator for avionics applications is introduced. The dynamics of such a device under load variations are primarily determined by the throttle between the oil chamber and the gas chamber. During operation, gas is absorbed by the oil upon compression and desorbed upon expansion, which are processes that extend over time and entail hysteresis. It is found that the assumption of isothermal conditions is sufficient. An excellent alignment is achieved by the model and the measured hysteresis across diverse drop test scenarios, adjusting a single parameter to a value that is physically reasonable. The standard deviation of the error in pressure is \({\sigma _{p}=0.49\,\textrm{bar}}\) σ p = 0.49 bar . Moreover, the model rests on thermodynamic considerations and experimental gas solubility data, while it is consistent with other laboratory data from the literature.