<p>Nickel–chromium (Ni–Cr) alloys offer high strength, wear resistance, shape-memory effect, and broad clinical applications. This study evaluates the effect of pre-annealing on their electrochemical corrosion behavior. Samples were annealed at 500 °C and 700 °C and compared with a non-annealed reference. Microstructure and composition were analyzed using X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX), while corrosion behavior was examined by open-circuit potential (OCP), potentiodynamic polarization (PDP), and electrochemical impedance spectroscopy (EIS). Annealing at 500 °C and 700 °C resulted in lattice expansion (from 3.551 Å to 3.561 Å) and a reduction in crystallite size (from 9.40&#xa0;nm to 8.10&#xa0;nm), accompanied by chemical inhomogeneity leading to degradation of the passive oxide layer. These changes accelerated corrosion: compared to the non-annealed alloy (0.0125 mm/year), the rate increased to 0.0356 mm/year at 500 °C and 0.313 mm/year at 700 °C. Concurrently, passive current density (I<sub>pass</sub>) doubled from 20 to 40 <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11043_2025_9819_Article_IEq1.gif" Format="GIF" Height="12" Rendition="HTML" Resolution="72" Type="Linedraw" Width="15" /> </InlineMediaObject> <EquationSource Format="MATHML"><math> <mi>μ</mi> </math></EquationSource> <EquationSource Format="TEX">$\mu $</EquationSource> </InlineEquation>A cm<sup>−2</sup>, while the Pitting potential (E<sub>pirs</sub>) shifted from +0.290 mV to –0.287 mV, indicating weaker passivation. EIS confirmed declining charge transfer resistance with temperature. Post-corrosion surface analysis confirmed these findings: SEM revealed increased roughness and defects, while EDX detected reduced oxygen content, consistent with thinning of the protective oxide film after annealing. Thus, high-temperature pre-annealing, therefore, markedly degrades corrosion resistance, underscoring the need for optimized heat treatment in dental applications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Effect of pre-annealing temperature on the microstructure and corrosion behavior of Ni88.6-Cr11.4 alloy for biomedical applications

  • Irfan Liaquat,
  • Warda Mushtaq,
  • Abdul Munam Khan,
  • Tehmina Bashir,
  • Uzma Zahoor

摘要

Nickel–chromium (Ni–Cr) alloys offer high strength, wear resistance, shape-memory effect, and broad clinical applications. This study evaluates the effect of pre-annealing on their electrochemical corrosion behavior. Samples were annealed at 500 °C and 700 °C and compared with a non-annealed reference. Microstructure and composition were analyzed using X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX), while corrosion behavior was examined by open-circuit potential (OCP), potentiodynamic polarization (PDP), and electrochemical impedance spectroscopy (EIS). Annealing at 500 °C and 700 °C resulted in lattice expansion (from 3.551 Å to 3.561 Å) and a reduction in crystallite size (from 9.40 nm to 8.10 nm), accompanied by chemical inhomogeneity leading to degradation of the passive oxide layer. These changes accelerated corrosion: compared to the non-annealed alloy (0.0125 mm/year), the rate increased to 0.0356 mm/year at 500 °C and 0.313 mm/year at 700 °C. Concurrently, passive current density (Ipass) doubled from 20 to 40 μ $\mu $ A cm−2, while the Pitting potential (Epirs) shifted from +0.290 mV to –0.287 mV, indicating weaker passivation. EIS confirmed declining charge transfer resistance with temperature. Post-corrosion surface analysis confirmed these findings: SEM revealed increased roughness and defects, while EDX detected reduced oxygen content, consistent with thinning of the protective oxide film after annealing. Thus, high-temperature pre-annealing, therefore, markedly degrades corrosion resistance, underscoring the need for optimized heat treatment in dental applications.