<p>Objective: To evaluate the alignment between self-reported confidence of large language models (LLM) and their accuracy in answering medical multiple-choice questions. Materials and Methods: We prompted six LLMs (GPT-5, GPT-5-mini, GPT-5-nano, GPT-4o, Claude Sonnet 4.5, and Gemini 2.5) to answer MedMCQA items and report confidence scores. Based on 12,000 LLM responses, we calculated Expected Calibration Errors (ECE) by averaging absolute differences between observed accuracy and predicted confidence. Results: Mean ECE differed by model (Claude Sonnet 4.5 best: 0.06; Gpt-4o worst: 0.127) and varied across specialties (“Skin” best: 0.041; “Social &amp; Preventive Medicine” worst: 0.141). Accuracy of examined LLMs showed analogous variation between specialties. Discussion: Our results demonstrate that high accuracy does not guarantee reliable uncertainty estimation. We identified substantial heterogeneity across medical specialties, where pooled metrics masked a threefold ECE increase between best- and worst-performing domains. Conclusion: We recommend incorporating calibration reporting into LLM evaluations, as larger models exhibit improved “self-knowledge”, but uneven overconfidence persists.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Calibration of Self-Reported Confidence and Accuracy of Large Language Models in Medical Question Answering

  • Sebastian Daniel Boie,
  • Florian Reis,
  • Nicolas Frey,
  • Elias Grünewald,
  • Felix Balzer

摘要

Objective: To evaluate the alignment between self-reported confidence of large language models (LLM) and their accuracy in answering medical multiple-choice questions. Materials and Methods: We prompted six LLMs (GPT-5, GPT-5-mini, GPT-5-nano, GPT-4o, Claude Sonnet 4.5, and Gemini 2.5) to answer MedMCQA items and report confidence scores. Based on 12,000 LLM responses, we calculated Expected Calibration Errors (ECE) by averaging absolute differences between observed accuracy and predicted confidence. Results: Mean ECE differed by model (Claude Sonnet 4.5 best: 0.06; Gpt-4o worst: 0.127) and varied across specialties (“Skin” best: 0.041; “Social & Preventive Medicine” worst: 0.141). Accuracy of examined LLMs showed analogous variation between specialties. Discussion: Our results demonstrate that high accuracy does not guarantee reliable uncertainty estimation. We identified substantial heterogeneity across medical specialties, where pooled metrics masked a threefold ECE increase between best- and worst-performing domains. Conclusion: We recommend incorporating calibration reporting into LLM evaluations, as larger models exhibit improved “self-knowledge”, but uneven overconfidence persists.