<p>To advance the understanding of helium transport physics, helium neutral beam (He-NB) experiments were initiated in the Large Helical Device (LHD) during the FY2021 experimental campaign. To facilitate these investigations, modifications were implemented in both the impurity exhaust system and the neutral beam (NB) injection system, enabling the use of the helium beam in a typical fusion experimental environment. In the positive-ion-source-based NB system—originally designed for hydrogen and deuterium beams—the gas supply lines were adapted to introduce helium and argon into the ion sources, while argon was injected into the neutralizer cells. These modifications allowed for the injection of a high current and high focused 78&#xa0;keV He-NB into the plasma. To improve helium exhaust efficiency at main vessel, turbo-molecular pumps were installed, increasing the effective pumping speed by approximately 1.4 times. During He-NB operation, a gradual decrease in the arc current of the NB ion source was observed with each discharge. This effect was attributed to the formation of helium bubbles on the tungsten filament surface, and a recovery method using argon gas discharges was successfully demonstrated. Plasma heating by He-NB injection was confirmed, and both energetic helium ions and bulk helium ions were successfully measured. Their spatial distributions were also observed. These results contribute to a deeper understanding of helium behavior in fusion plasma and offer valuable insights for future helium transport studies.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Recipe of Helium Neutral Beam Injection for Studying Helium Transport in LHD

  • Yutaka Fujiwara,
  • Kenichi Nagaoka,
  • Gen Motojima,
  • Hiroyuki Yamaguchi,
  • Mamoru Sato,
  • Naoyuki Suzuki,
  • Hiromi Kato,
  • Ryuichi Sakamoto,
  • Daisuke Nagata,
  • Shuji Kamio,
  • Masaki Osakabe,
  • Katsuyoshi Tsumori,
  • Haruhisa Nakano,
  • Mikiro Yoshinuma,
  • Tatsuya Kobayashi,
  • Katsumi Ida

摘要

To advance the understanding of helium transport physics, helium neutral beam (He-NB) experiments were initiated in the Large Helical Device (LHD) during the FY2021 experimental campaign. To facilitate these investigations, modifications were implemented in both the impurity exhaust system and the neutral beam (NB) injection system, enabling the use of the helium beam in a typical fusion experimental environment. In the positive-ion-source-based NB system—originally designed for hydrogen and deuterium beams—the gas supply lines were adapted to introduce helium and argon into the ion sources, while argon was injected into the neutralizer cells. These modifications allowed for the injection of a high current and high focused 78 keV He-NB into the plasma. To improve helium exhaust efficiency at main vessel, turbo-molecular pumps were installed, increasing the effective pumping speed by approximately 1.4 times. During He-NB operation, a gradual decrease in the arc current of the NB ion source was observed with each discharge. This effect was attributed to the formation of helium bubbles on the tungsten filament surface, and a recovery method using argon gas discharges was successfully demonstrated. Plasma heating by He-NB injection was confirmed, and both energetic helium ions and bulk helium ions were successfully measured. Their spatial distributions were also observed. These results contribute to a deeper understanding of helium behavior in fusion plasma and offer valuable insights for future helium transport studies.