Purpose <p>To evaluate the visual outcomes, dysphotopsia profile, and patient satisfaction following bilateral implantation of the AcrySof IQ Vivity intraocular lens (IOL) in patients with early or intermediate age-related macular degeneration (AMD).</p> Methods <p>Prospective, single-center study. 24 patients (48 eyes) with bilateral cataract and early or intermediate AMD who underwent bilateral implantation of the AcrySof IQ Vivity IOL. The primary outcome was monocular corrected distance visual acuity (mCDVA). Secondary endpoints were distance-corrected and unaided monocular and binocular visual acuity at 4&#xa0;m, 66&#xa0;cm, and 40&#xa0;cm, monocular defocus curve, subjective dysphotopsia (McAlinden QoV questionnaire) and haloes perception (Aston Halometer), visual function (Catquest-9SF), and spectacle independence (IOLSAT).</p> Results <p>At 3&#xa0;months postoperatively, mCDVA improved significantly from 0.30 to 0.00 logMAR (p &lt; 0.001). Binocular uncorrected distance and intermediate visual acuities of ≤ 0.2 logMAR were achieved by 23 (95.8%) and 17 (70.8%) patients, respectively. The defocus curve showed visual acuity of 0.2 logMAR across a range of + 1.40 D to -1.72 D. Bothersome dysphotopsias significantly decreased, with QoV scores improving from 58.5 (IQR: 26.1–66.5) to 0.00 (IQR: 0.00–14.3) (p &lt; 0.05). The mean halo eccentricity was 0.50 ± 0.08 degrees. Spectacle independence was reported by 22 (91.7%), 20 (83.3%), and 13 (54.2%) patients for distance, intermediate, and near tasks, respectively. Overall, 22 (91.7%) patients reported postoperative satisfaction.</p> Conclusion <p>The AcrySof IQ Vivity IOL demonstrated favourable outcomes in patients with early or intermediate AMD, offering a meaningful range of spectacle-free vision with minimal photic phenomena.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Bilateral implantation of extended depth of focus intraocular lens in patients with early or intermediate age-related macular degeneration

  • Nicolò Ciarmatori,
  • Antonio Cartabellotta,
  • Ginevra Giovanna Adamo,
  • Camilla Biffi,
  • Pietro Maria Talli,
  • Marco Pellegrini,
  • Marco Mura

摘要

Purpose

To evaluate the visual outcomes, dysphotopsia profile, and patient satisfaction following bilateral implantation of the AcrySof IQ Vivity intraocular lens (IOL) in patients with early or intermediate age-related macular degeneration (AMD).

Methods

Prospective, single-center study. 24 patients (48 eyes) with bilateral cataract and early or intermediate AMD who underwent bilateral implantation of the AcrySof IQ Vivity IOL. The primary outcome was monocular corrected distance visual acuity (mCDVA). Secondary endpoints were distance-corrected and unaided monocular and binocular visual acuity at 4 m, 66 cm, and 40 cm, monocular defocus curve, subjective dysphotopsia (McAlinden QoV questionnaire) and haloes perception (Aston Halometer), visual function (Catquest-9SF), and spectacle independence (IOLSAT).

Results

At 3 months postoperatively, mCDVA improved significantly from 0.30 to 0.00 logMAR (p < 0.001). Binocular uncorrected distance and intermediate visual acuities of ≤ 0.2 logMAR were achieved by 23 (95.8%) and 17 (70.8%) patients, respectively. The defocus curve showed visual acuity of 0.2 logMAR across a range of + 1.40 D to -1.72 D. Bothersome dysphotopsias significantly decreased, with QoV scores improving from 58.5 (IQR: 26.1–66.5) to 0.00 (IQR: 0.00–14.3) (p < 0.05). The mean halo eccentricity was 0.50 ± 0.08 degrees. Spectacle independence was reported by 22 (91.7%), 20 (83.3%), and 13 (54.2%) patients for distance, intermediate, and near tasks, respectively. Overall, 22 (91.7%) patients reported postoperative satisfaction.

Conclusion

The AcrySof IQ Vivity IOL demonstrated favourable outcomes in patients with early or intermediate AMD, offering a meaningful range of spectacle-free vision with minimal photic phenomena.