Objective <p>The study aimed to assess the effectiveness of micro-CT in assessing the removal of obturation material from canals filled with gutta-percha and bioceramic sealer.</p> Materials and methods <p>Forty mandibular premolars were prepared with the Reciproc Blue R25 system and obturated with the single cone technique and Bio C Sealer. The specimens were divided into four groups (n = 10): Group GRI—Reciproc Blue R40 and Irrisonic; Group GRXP—Reciproc Blue R40 and XP Endo Finisher R; Group GRFI—Reciproc Blue R40, Flatsonic and final rinsing with Irrisonic; Group GRFXP—Reciproc Blue R40 and Flatsonic insert and final rinsing with XP Endo Finisher R. All samples were subjected to micro-CT after obturation, retreatment and final irrigation protocol. The one-way ANOVA test was used to compare the remaining filler volumes between each phase of the study and a repeated measures ANOVA was performed for each experimental group, followed by a Sidak post-test.</p> Results <p>There was a difference in the remaining volume of obturation material among all experimental phases (p &lt; 0.05) for all groups. The use of the Flatsonic insert did not result in better cleaning.</p> Conclusion <p>The Irrisonic and XP Endo Finisher R systems effectively improve cleaning after retreatment with a reciprocating system, regardless of whether the Flatsonic insert is used.</p> Clinical relevance <p>The Irrisonic and XP Endo Finisher R systems enhance debris removal and antibacterial efficacy during endodontic retreatment. Their use aids practitioners in optimizing treatment protocols, promoting superior patient outcomes and increased success rates in complex clinical cases.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Efficacy of irrisonic, XP endo finisher R, and flatsonic in bioceramic sealer removal: a micro-CT study

  • Caroline Beatriz Farias-Silva,
  • Ana Grasiela Limoeiro,
  • Priscilla Gouveia,
  • Marília Marceliano-Alves,
  • Carlos Eduardo Fontana,
  • Rina Andrea Pelegrine,
  • Daniel Guimarães Pedro Rocha,
  • Ricardo Lopes,
  • Alexandre Sigrist De Martin,
  • Carlos Eduardo da Silveira Bueno

摘要

Objective

The study aimed to assess the effectiveness of micro-CT in assessing the removal of obturation material from canals filled with gutta-percha and bioceramic sealer.

Materials and methods

Forty mandibular premolars were prepared with the Reciproc Blue R25 system and obturated with the single cone technique and Bio C Sealer. The specimens were divided into four groups (n = 10): Group GRI—Reciproc Blue R40 and Irrisonic; Group GRXP—Reciproc Blue R40 and XP Endo Finisher R; Group GRFI—Reciproc Blue R40, Flatsonic and final rinsing with Irrisonic; Group GRFXP—Reciproc Blue R40 and Flatsonic insert and final rinsing with XP Endo Finisher R. All samples were subjected to micro-CT after obturation, retreatment and final irrigation protocol. The one-way ANOVA test was used to compare the remaining filler volumes between each phase of the study and a repeated measures ANOVA was performed for each experimental group, followed by a Sidak post-test.

Results

There was a difference in the remaining volume of obturation material among all experimental phases (p < 0.05) for all groups. The use of the Flatsonic insert did not result in better cleaning.

Conclusion

The Irrisonic and XP Endo Finisher R systems effectively improve cleaning after retreatment with a reciprocating system, regardless of whether the Flatsonic insert is used.