Objectives <p>This study compared the silicone replica method with swept-source optical coherence tomography (SS-OCT) to analyze marginal adaptation and investigated the effect of the light incidence angle of SS-OCT on measurement precision.</p> Materials and methods <p>A typodont-prepared mandibular right first molar was scanned using an intraoral scanner (Trios 3). Fourteen crowns were fabricated from CAD/CAM resin blocks (Katana Avencia P) using a 5-axis milling machine (DWX-50). Marginal adaptation at the buccal, lingual, mesial, and distal points was assessed using the silicone replica method and SS-OCT at light incidence angles of 60°, 75°, and 90°. Statistical comparisons were performed using two-way analysis of variance (ANOVA) and t-tests with Bonferroni correction, and t-tests at a significance level of 0.05.</p> Results <p>At 60°, SS-OCT showed significantly larger marginal discrepancies than the silicone replica method at the buccal, lingual, and mesial points (<i>p</i> &lt; 0.05). At 75°, only the lingual point showed a significantly larger value than the silicone replica method (<i>p</i> &lt; 0.05). At 90°, no significant differences were observed between the SS-OCT and silicone replica methods (<i>p</i> &gt; 0.05). Marginal discrepancy values increased as the angle changed from 90° to 75° to 60°, with significant differences between 60° and 75° and between 60° and 90° at the buccal and lingual points (<i>p</i> &lt; 0.05).</p> Conclusions <p>SS-OCT is a viable alternative to the silicone replica method for assessing marginal adaptation at an incidence angle of 90 °.</p> Clinical relevance <p>SS-OCT, a non-invasive method, has the potential to be applied clinically for evaluating marginal fit in indirect restorations in vivo.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Marginal adaptation analysis of CAD/CAM resin crown with non-invasive methods

  • Chen Zeng,
  • Tomoko Tabata,
  • Rena Takahashi,
  • Masaomi Ikeda,
  • Junichi Shinagawa,
  • Hisaichi Nakagawa,
  • Yumi Tsuchida,
  • Shunsuke Takano,
  • Yasunori Sumi,
  • Yasushi Shimada

摘要

Objectives

This study compared the silicone replica method with swept-source optical coherence tomography (SS-OCT) to analyze marginal adaptation and investigated the effect of the light incidence angle of SS-OCT on measurement precision.

Materials and methods

A typodont-prepared mandibular right first molar was scanned using an intraoral scanner (Trios 3). Fourteen crowns were fabricated from CAD/CAM resin blocks (Katana Avencia P) using a 5-axis milling machine (DWX-50). Marginal adaptation at the buccal, lingual, mesial, and distal points was assessed using the silicone replica method and SS-OCT at light incidence angles of 60°, 75°, and 90°. Statistical comparisons were performed using two-way analysis of variance (ANOVA) and t-tests with Bonferroni correction, and t-tests at a significance level of 0.05.

Results

At 60°, SS-OCT showed significantly larger marginal discrepancies than the silicone replica method at the buccal, lingual, and mesial points (p < 0.05). At 75°, only the lingual point showed a significantly larger value than the silicone replica method (p < 0.05). At 90°, no significant differences were observed between the SS-OCT and silicone replica methods (p > 0.05). Marginal discrepancy values increased as the angle changed from 90° to 75° to 60°, with significant differences between 60° and 75° and between 60° and 90° at the buccal and lingual points (p < 0.05).

Conclusions

SS-OCT is a viable alternative to the silicone replica method for assessing marginal adaptation at an incidence angle of 90 °.

Clinical relevance

SS-OCT, a non-invasive method, has the potential to be applied clinically for evaluating marginal fit in indirect restorations in vivo.