<p> A&#xa0;paper sensor, a gold nanoparticles-based lateral flow immunochromatographic assay (GNPs-LFIA), was successfully established for the rapid quantitative detection of dibenz[a,h]anthracene (DBA) in drilling fluids (DFs). Computational analysis was employed to rationally design a novel hapten to effectively expose the active site of DBA, resulting in the successful development of a monoclonal antibody with high sensitivity and specificity. The half-maximum inhibitory concentration was 5.814&#xa0;ng/mL. Then, the GNPs-LFIA was established following the optimization of the extraction agent and method. The limit of detection for DF samples was 0.273&#xa0;mg/kg. Recovery experiments showed a high level of consistency with the results obtained by high-performance liquid chromatography-fluorescence detection, which indicated that the established GNPs-LFIA offered exceptional accuracy and reliability. Consequently, this method is well-suited for the rapid screening and determination of DBA in oilfield chemicals and presents a technical solution to identify polycyclic aromatic hydrocarbons.</p> Graphical abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Quantitative immunosensor for dibenz[a,h]anthracene on-site detection in oilfield chemicals based on computer-aided antibody

  • Jiaxun Li,
  • Haifeng Chen,
  • Yong Shu,
  • Luming Jiang,
  • Wei Gao,
  • Hua Kuang,
  • Chuanlai Xu,
  • Lingling Guo

摘要

A paper sensor, a gold nanoparticles-based lateral flow immunochromatographic assay (GNPs-LFIA), was successfully established for the rapid quantitative detection of dibenz[a,h]anthracene (DBA) in drilling fluids (DFs). Computational analysis was employed to rationally design a novel hapten to effectively expose the active site of DBA, resulting in the successful development of a monoclonal antibody with high sensitivity and specificity. The half-maximum inhibitory concentration was 5.814 ng/mL. Then, the GNPs-LFIA was established following the optimization of the extraction agent and method. The limit of detection for DF samples was 0.273 mg/kg. Recovery experiments showed a high level of consistency with the results obtained by high-performance liquid chromatography-fluorescence detection, which indicated that the established GNPs-LFIA offered exceptional accuracy and reliability. Consequently, this method is well-suited for the rapid screening and determination of DBA in oilfield chemicals and presents a technical solution to identify polycyclic aromatic hydrocarbons.

Graphical abstract