<p>A&#xa0;self-powered dual-electrode aptasensor was developed&#xa0;for the detection of tumor marker carcinoembryonic antigen (CEA). The composite BiVO<sub>4</sub>/ZnIn<sub>2</sub>S<sub>4</sub>, which is capable of forming a Z-scheme heterojunction, was chosen as the photoanode, and the AuNP/CuBi<sub>2</sub>O<sub>4</sub> complex was chosen as the photocathode&#xa0;in photoelectrochemical&#xa0;(PEC)&#xa0;detection. The experiments showed that the constructed self-powered dual-electrode system had a good photoelectric response to white light, and the photocurrent signal of the photocathode was significantly enhanced under the influence of the photoanode. The introduction of G-quadruplex/hemin DNAzyme through aptamer recognition resulted in the generation of insoluble species through catalytic reaction, which led to a significant decrease in the photocurrent, and achieved a highly sensitive detection of the target CEA with a detection limit of 0.021&#xa0;pg/mL. At the same time, the developed photocathode detection exhibited good selectivity and could effectively avoid interference, making it suitable for real sample analysis. It is expected that this study can facilitate the application of PEC sensors in point-of-care (POC) diagnosis for life analysis.</p> Graphical Abstract <p>Self-powered dual-photoelectrode photoelectrochemical aptasensor amplified by hemin/ G-quadruplex-based DNAzyme</p> <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Self-powered dual-photoelectrode photoelectrochemical aptasensor amplified by hemin/G-quadruplex-based DNAzyme

  • Yibo Huang,
  • Weishen Lu,
  • Shengjun Che,
  • Xiaoru Zhang,
  • Xunyi Yuan

摘要

A self-powered dual-electrode aptasensor was developed for the detection of tumor marker carcinoembryonic antigen (CEA). The composite BiVO4/ZnIn2S4, which is capable of forming a Z-scheme heterojunction, was chosen as the photoanode, and the AuNP/CuBi2O4 complex was chosen as the photocathode in photoelectrochemical (PEC) detection. The experiments showed that the constructed self-powered dual-electrode system had a good photoelectric response to white light, and the photocurrent signal of the photocathode was significantly enhanced under the influence of the photoanode. The introduction of G-quadruplex/hemin DNAzyme through aptamer recognition resulted in the generation of insoluble species through catalytic reaction, which led to a significant decrease in the photocurrent, and achieved a highly sensitive detection of the target CEA with a detection limit of 0.021 pg/mL. At the same time, the developed photocathode detection exhibited good selectivity and could effectively avoid interference, making it suitable for real sample analysis. It is expected that this study can facilitate the application of PEC sensors in point-of-care (POC) diagnosis for life analysis.

Graphical Abstract

Self-powered dual-photoelectrode photoelectrochemical aptasensor amplified by hemin/ G-quadruplex-based DNAzyme