Predicting extubation failure in neonates: The role of lung ultrasound and corrected gestational age in safe weaning in the NICU
摘要
To evaluate the accuracy of the lung ultrasound score (LUS) in predicting ventilatory weaning failure during neonatal hospitalization in the NICU and to identify factors associated with weaning failure, including corrected gestational age (CGA). This prospective, longitudinal, pragmatic and observational cohort study included neonates on mechanical ventilation for at least 48 h. The primary outcome was the accuracy of lung ultrasound in predicting 3-day weaning failure, with the ROC curve used to determine the best LUS cutoff (sensitivity and specificity). Among 55 neonates, the pre-extubation LUS did not show statistical significance in predicting weaning failure (AUC 0.61; 95% CI: 0.46–0.76, p = 0,169). In the subgroup analysis, a score ≥ 4 suggests the need for ventilatory support after extubation (area under the curve [AUC] = 0.91, 95% CI: 0.80–1.0, p < 0.001) in neonates with GA ≥ 28 weeks. In extremely preterm infants, the pre-extubation LUS was not statistically significant in predicting weaning failure (AUC = 0.38, 95% CI: 0–0.77, p = 0.535). In contrast, CGA ≥ 28.7 weeks at extubation was predictor of successful weaning within 3 days (AUC = 0.95, 95% CI: 0.85–1.0, p < 0.001).
Conclusion: LUS show promise in predicting weaning failure, though its accuracy may be limited in extremely preterm infants, highlighting the need for further well-powered studies. CGA at extubation also emerges as a key consideration in this population, warranting confirmation through robust future research.