Purpose <p>To evaluate the feasibility and diagnostic performance of a multimodal large language model (GPT-4.1) in detecting pediatric airway foreign body aspiration (FBA) using real-world clinical and radiographic data.</p> Methods <p>This retrospective cohort study included 58 pediatric patients evaluated for suspected airway FBA at a tertiary academic hospital between 2015 and 2024. Each case combined structured clinical data and chest radiographs obtained at the time of emergency-department presentation, with bronchoscopy serving as the diagnostic reference standard. GPT-4.1, a vision-enabled large language model, classified cases as right-bronchus aspiration, left-bronchus aspiration, or no aspiration. Model performance was assessed using accuracy, precision, recall, and F1-score.</p> Results <p>The model achieved an overall accuracy of 62.3%, with precision of 23.3%, recall of 19.0%, and an F1-score of 0.21. While it correctly identified 34 of 46 cases without aspiration, it detected only 4 of 12 confirmed bronchial-aspiration cases and missed all left-bronchus aspirations.</p> Conclusions <p>This proof-of-concept feasibility study highlights substantial limitations of a general-purpose multimodal AI model in pediatric airway triage. The low recall and high misclassification rates suggest that vision-enabled language models require task-specific training and rigorous validation before clinical implementation. Nevertheless, when used as an adjunct rather than a replacement for bronchoscopy, such models may eventually support triage decisions in resource-limited settings if further optimized and prospectively validated.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Cautionary lessons from real-world testing of GPT-4.1 AI for pediatric foreign body aspiration

  • Sholem Hack,
  • Rebecca Attal,
  • Dana Elazar,
  • Yaniv Alon,
  • Raphael Meyuchas,
  • Adva Livne,
  • Ory Madgar,
  • Mor Saban

摘要

Purpose

To evaluate the feasibility and diagnostic performance of a multimodal large language model (GPT-4.1) in detecting pediatric airway foreign body aspiration (FBA) using real-world clinical and radiographic data.

Methods

This retrospective cohort study included 58 pediatric patients evaluated for suspected airway FBA at a tertiary academic hospital between 2015 and 2024. Each case combined structured clinical data and chest radiographs obtained at the time of emergency-department presentation, with bronchoscopy serving as the diagnostic reference standard. GPT-4.1, a vision-enabled large language model, classified cases as right-bronchus aspiration, left-bronchus aspiration, or no aspiration. Model performance was assessed using accuracy, precision, recall, and F1-score.

Results

The model achieved an overall accuracy of 62.3%, with precision of 23.3%, recall of 19.0%, and an F1-score of 0.21. While it correctly identified 34 of 46 cases without aspiration, it detected only 4 of 12 confirmed bronchial-aspiration cases and missed all left-bronchus aspirations.

Conclusions

This proof-of-concept feasibility study highlights substantial limitations of a general-purpose multimodal AI model in pediatric airway triage. The low recall and high misclassification rates suggest that vision-enabled language models require task-specific training and rigorous validation before clinical implementation. Nevertheless, when used as an adjunct rather than a replacement for bronchoscopy, such models may eventually support triage decisions in resource-limited settings if further optimized and prospectively validated.